R99-04 FOR G5F Omron, R99-04 FOR G5F Datasheet - Page 4

MOUNTING BRACKET -G7J

R99-04 FOR G5F

Manufacturer Part Number
R99-04 FOR G5F
Description
MOUNTING BRACKET -G7J
Manufacturer
Omron
Series
G7Jr

Specifications of R99-04 FOR G5F

Accessory Type
Mounting Bracket, Plate
Associated Relay Series
G7J
Termination Style
Screw
Mounting Style
Screw
Width
28 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
G7J Series
For Use With
G7J-4A-TDC6 - RELAY GP PWR 4PST QC TERMG7J-4A-TDC48 - RELAY GP PWR 4PST QC TERMG7J-4A-TDC24 - RELAY GP PWR 4PST QC TERMG7J-4A-TDC12 - RELAY GP PWR 4PST QC TERMG7J-4A-TDC100 - RELAY GP PWR 4PST QC TERMG7J-4A-TAC24 - RELAY GP PWR 4PST QC TERMG7J-4A-TAC200/240 - RELAY GP PWR 4PST QC TERMG7J-4A-TAC100/120 - RELAY GP PWR 4PST QC TERMG7J-4A-BDC48 - RELAY GP PWR 4PST SCREW TERMG7J-3A1B-TDC6 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-TDC48 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-TDC12 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-TDC100 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-TAC50 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-TAC24 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-TAC200/240 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-TAC100/120 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-BDC12 - RELAY PWR 3PST-NO/1NC 25AG7J-3A1B-BAC24 - RELAY PWR 3PST-NO/1NC 25AG7J-2A2B-TDC6 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TDC48 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TDC24 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TDC12 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TDC100 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TAC50 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TAC24 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TAC200/240 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TAC100/120 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-BDC12 - RELAY PWR DPST-NO/NC 25AG7J-2A2B-BDC110 - RELAY PWR DPST-NO/NC 25AG7J-2A2B-BDC100 - RELAY PWR DPST-NO/NC 25AG7J-2A2B-BAC50 - RELAY PWR DPST-NO/NC 25AG7J-4A-B-DC24 - RELAY PWR 4PST 25A 24VDCG7J-4A-B-DC12 - RELAY PWR 4PST 25A 12VDCG7J-4A-B-AC24 - RELAY PWR 4PST 25A 24VACG7J-4A-BAC200/240 - RELAY PWR 4PST 25A 230VACG7J-4A-BAC100/120 - RELAY PWR 4PST 25A 120VACG7J-3A1B-B-DC24 - RELAY PWR 3PST-NO/1NC 25A 24VDCG7J3A1BBAC200/240 - RELAY PWR 3PST-NO/1NC 25A 230VACG7J3A1BBAC100/120 - RELAY PWR 3PST-NO/1NC 25A 120VACG7J-2A2B-B-DC48 - RELAY PWR DPST-NO/NC 25A 48VDCG7J-2A2B-B-DC24 - RELAY PWR DPST-NO/NC 25A 24VACG7J-2A2B-B-AC24 - RELAY PWR DPST-NO/NC 25A 24VACG7J2A2BBAC200/240 - RELAY PWR DPST-NO/NC 25A 230VACG7J2A2BBAC100/120 - RELAY PWR DPST-NO/NC 25A 120VAC
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R99-04
R99-04
R99-04FORG5F
R9904
R9904FORG5F
Z1238
Note: 1. The above values are all initial values.
■ Approved Standards
The G7J satisfies the following international standards. Approval for some international markings and symbols are still pending, however, and in-
formation on them will be added when they are approved.
UL (File No. E41643)
CSA (File No. LR35535)
Note: *These ratings are bifurcated contact ratings.
Reference
UL approval:
CSA approval: CSA C22.2 No. 14 for industrial control devices
VDE (File No. 5381UG)
Note: Add the suffix “-KM” to the model number when ordering.
Reference
VDE approval: EN60255-1-00: 1997
24 to 265 VAC
6 to 110 VDC
G7J-4A-B(P) (T)
G7J-2A2B(P) (T)
G7J-3A1B-B(P) (T)
2. The contact resistance was measured with 1 A at 5 VDC using the voltage drop method.
3. The operate and the release times were measured with the rated voltage imposed with any contact bounce ignored at an ambient tem-
4. The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for checking the dielectric
5. The electrical endurance was measured at an ambient temperature of 23°C.
6. This value was measured at a switching frequency of 60 operations per minute.
Coil ratings
perature of 23°C.
strength.
Model
UL508 for industrial control devices
EN60255-23: 1996
NO contact
NC contact
6, 12, 24, 48, 100 VDC
24, 50, 100 to 120, 200 to 240 VAC
Coil ratings
25 A 277 VAC, Resistive
25 A 120 VAC, General Use
25 A 277 VAC, General Use
25 A 240 VAC, General Use
1.5 kW 120 VAC, Tungsten
1.5 hp 120 VAC
3 hp 240/265/277 VAC
3-phase 3 hp 240/265/277 VAC
3-phase 5 hp 240/265/277 VAC
20FLA/120LRA 120 VAC
17FLA/102LRA 277 VAC
TV-10 120 VAC
25 A 30 VDC, Resistive
*1 A 277 VAC, General Use
8 A 277 VAC, Resistive
8 A 120 VAC, General Use
8 A 277 VAC, General Use
8 A 30 VDC, Resistive
*1 A 277 VAC, General Use
Contact ratings
25 A 240 VAC cosφ = 0.4
25 A 240 VAC cosφ = 1
25 A 30 VDC L/R ≥ 1
NO contact
Contact ratings
8 A 240 VAC cosφ = 0.4
8 A 240 VAC cosφ = 1
8 A 30 VDC L/R ≥ 1
30,000
100,000
6,000
1,000
30,000
25,000
30,000
6,000
30,000
6,000
NC contact
Number of test
operations
G7J
4

Related parts for R99-04 FOR G5F