MM4XP-AC100/110 Omron, MM4XP-AC100/110 Datasheet - Page 6

no-image

MM4XP-AC100/110

Manufacturer Part Number
MM4XP-AC100/110
Description
RELAY
Manufacturer
Omron
Series
MMr
Datasheet

Specifications of MM4XP-AC100/110

Relay Type
General Purpose
Contact Form
4PDT (4 Form C)
Contact Rating (current)
7A
Switching Voltage
250VAC, 250VDC - Max
Coil Type
Standard
Coil Current
51mA
Coil Voltage
110VAC
Turn On Voltage (max)
88 VAC
Turn Off Voltage (min)
33 VAC
Mounting Type
Socket
Termination Style
14 Pin Socketable
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
7A @ 110VDC
Control On Voltage (max)
88 VAC
Control Off Voltage (min)
33 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MM4XPAC100110NC
Contacts (Conforming to Auxiliary Power Relay Specifications)
Note: 1. A model for DC loads is not in stable operation when switching an inductive load within a operating current range between 0.5 and 2.5 A
■ Characteristics
Standard Relays
Note: 1. The data shown above are initial values.
Contact type
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
(reference value)
Contact resistance (See note 2.)
Operate time (See note 3.)
Release time (See note 3.)
Max. operating frequency
Insulation resistance (See note 4.)
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
2. If L/R exceeds 7 ms when switching DC inductive loads, an arc-breaking time of up to 50 ms must be considered in application and the
2. The contact resistance was measured with 1 A at 5 VDC using the voltage drop method.
3. The operate or release time was measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature
4. The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for checking the dielectric
5. The electrical endurance was measured at an ambient temperature of 23°C.
at a minimum of 125 VDC, where the load cannot be switched.
circuit must be designed to ensure that an arc-breaking time of 50 ms is not exceeded.
of 23°C.
strength.
Item
Item
Single
Ag
5 A at 220 VAC, 5 A at 24 VDC
5 A
250 VAC, 250 VDC
5 A
1,100 VA, 120 W, 30 W (L/R = 40 ms)
Resistive load
25 mΩ max.
AC: 25 ms max. DC: 50 ms max.
30 ms max. (100 ms max. for Built-in Diode Relays)
Mechanical:7,200 operations/hr
Electrical:1,800 operations/hr (under rated load)
100 MΩ min. (at 500 VDC)
1,500 VAC, 50/60 Hz for 1 min between contacts of same polarity
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity (and between coil and contacts)
Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 50 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 100 m/s
Mechanical: 5,000,000 operations min. (at 7,200 operations/hr)
Electrical:
Operating:–10°C to 55°C (with no icing or condensation)
Operating:5% to 85%
Standard models: DC-switching models
MM2 approx. 160 g
MM3 approx. 270 g
MM4 approx. 300 g
MM2P approx. 220 g
MM3P approx. 360 g
MM4P approx. 410 g
MM4P-JD
500,000 operations min. (at 1,800 operations/hr under rated load) (See note 5.)
(cosφ = 0.4, L/R = 7 ms)
Open Relays
Inductive load
2
2
MM2X approx. 165 g
MM3X approx. 275 g
MM4X approx. 310 g
5 A at 110 VDC
20 VA, 550 W, 40 W (L/R = 40 ms)
MM2XP approx. 225 g
MM3XP approx. 395 g
MM4XP approx. 420 g
Resistive load
50 mΩ max.
MM4XP-JD
Cased Relays
(cosφ = 0.4, L/R = 7 ms)
Inductive load
MM
6