MM2XP-D-DC24 Omron, MM2XP-D-DC24 Datasheet - Page 7

no-image

MM2XP-D-DC24

Manufacturer Part Number
MM2XP-D-DC24
Description
RELAY
Manufacturer
Omron
Series
MMr
Datasheet

Specifications of MM2XP-D-DC24

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
7A
Switching Voltage
250VAC, 250VDC - Max
Coil Type
Standard
Coil Current
87mA
Coil Voltage
24VDC
Turn On Voltage (max)
16.8 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
7A @ 110VDC
Control On Voltage (max)
16.8 VDC
Control Off Voltage (min)
2.4 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MM2XPDDC24

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MM2XP-D-DC24V
Manufacturer:
OMRON
Quantity:
12 000
Relays (Conforming to Auxiliary Power Relay Specifications)
Note: 1. The data shown above are initial values.
Engineering Data
■ Standard Relays
Contact resistance (See note 2.)
Operate time (See note 3.)
Release time (See note 3.)
Max. operating frequency
Insulation resistance (See note 4.)
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Error rate (level P)
(Reference value)
(See note 6.)
Ambient temperature
Ambient humidity
Weight
Maximum Switching Power
Open Relays
2. The contact resistance was measured with 1 A at 5 VDC using the voltage drop method.
3. The operate or release time was measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature
4. The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for checking the dielectric
5. The electrical endurance was measured at an ambient temperature of 23°C.
6. This value was measured at a switching frequency of 60 operations per minute.
of 23°C.
strength.
DC inductive
load L/R = 7 ms
DC resistive load
Switching voltage (V)
Item
MM@(B)
AC inductive
load
(cosφ = 0.4)
AC resistive load
50 mΩ max.
AC: 25 ms max., DC: 50 ms max.
30 ms max.
Mechanical:
Electrical:
100 MΩ min.
Between coil and contact:
Between contacts of different polarity: 2,000 VAC, 50/60 Hz for 1 minute
Between contacts of same polarity:
Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 22 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Destruction: 300 m/s
Malfunction: 30 m/s
Mechanical: 5,000,000 operations min. (at 1,800 operations/hr)
Electrical:
10 mA at 5 VDC
Operating: –10°C to 40°C (with no icing or condensation)
Operating: 5% to 85%
MM4P-JD: approx. 410 g
MM4XP-JD: approx. 420 g
500,000 operations min. (at 1,800 operations/hr with rated load) (see note 5)
1,800 operations/hr
1,800 operations/hr (under rated load)
2
2
Cased Relays
DC inductive
load L/R = 7 ms
2,000 VAC, 50/60 Hz for 1 minute
1,500 VAC, 50/60 Hz for 1 minute
Switching voltage (V)
MM@P(N, -D)
Cased Relays
AC inductive
load
(cosφ = 0.4)
DC resistive load
AC resistive load
MM
7