MM2XP-D DC125 Omron, MM2XP-D DC125 Datasheet - Page 10

no-image

MM2XP-D DC125

Manufacturer Part Number
MM2XP-D DC125
Description
RELAY
Manufacturer
Omron
Series
MMr
Datasheet

Specifications of MM2XP-D DC125

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
7A
Switching Voltage
250VAC, 250VDC - Max
Coil Type
Standard
Coil Current
16.8mA
Coil Voltage
125VDC
Turn On Voltage (max)
87.5 VDC
Turn Off Voltage (min)
12.5 VDC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
7A @ 110VDC
Control On Voltage (max)
87.5 VDC
Control Off Voltage (min)
12.5 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MM2XP-DDC125
MM2XPDDC125NC
MM2P AC (60 Hz)
Ambient Temperature vs.
Coil Temperature Rise
MM2P 110 VAC (60 Hz)
MM2P AC
Ambient Temperature vs. Must-operate
and Must-release Voltage
Malfunctioning Shock
Number of samples: 5
Measurement conditions:
Impose a shock of 100 m/s
the ±X, ±Y, and ±Z directions
three times each with the
Relay energized and not
energized to check the shock
values that cause the Relay
to malfunction.
NO contact
NC contact
Number of Relays: 5
Number of Relays: 5
Ambient temperature (°C)
Ambient temperature (°C)
2
in
Unit: m/s
Shock direction
Contact carry current
2
Must-operate voltage
Must-release voltage
(Improved Allen-Bradley Test Circuit)
MM4P 24 VDC
Contact Reliability
10
Contact load: 10 mA at 5 VDC
(resistive load)
Error rate l = 0.0202 x
−6
/operations (level Q)
Number of switching
operations (x 10
MM2P DC
MM2P DC
4
times)
Number of Relays: 5
Number of Relays: 5
Ambient temperature (°C)
Ambient temperature (°C)
(level N)
Contact load: 1 mA at
5 VDC (resistive load)
Error rate l = 0.2794
x 10
Contact carry current
−6
/operations
Must-operate voltage
Must-release voltage
Number of switching
operations (x 10
4
times)
MM
10

Related parts for MM2XP-D DC125