MM2XP AC200/(220) Omron, MM2XP AC200/(220) Datasheet - Page 5

no-image

MM2XP AC200/(220)

Manufacturer Part Number
MM2XP AC200/(220)
Description
RELAY
Manufacturer
Omron
Series
MMr
Datasheet

Specifications of MM2XP AC200/(220)

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
7A
Switching Voltage
250VAC, 250VDC - Max
Coil Type
Standard
Coil Current
17.5mA
Coil Voltage
220VAC
Turn On Voltage (max)
176 VAC
Turn Off Voltage (min)
66 VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
7A @ 110VDC
Control On Voltage (max)
176 VAC
Control Off Voltage (min)
66 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MM2XPAC200/(220)
MM2XPAC200220NC
Coils (Conforming to Auxiliary Power Relay Specifications)
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and ±15% for DC coil
■ Contact Ratings
Standard Relays
Note: This value is measured at 60 operations/min.
DC-switching Relays/Built-in Diode Relays
Note: 1. When switching DC inductive loads at 125 V or more, an unstable region exists for a contact current of between 0.5 and 2.5 A. The Relay will not turn OFF
AC
DC
Contact type
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
(reference value)
Minimum permissible load
(reference value) (See note.)
Contact type
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
(reference value)
Minimum permissible load
(reference value) (See note 3.)
Rated voltage
2. The AC coil resistance and coil inductance values are for reference only.
3. Performance characteristic data are measured at a coil temperature of 23°C.
4. The maximum voltage is one that is applicable instantaneously to the Relay coil at 23°C and not continuously.
2. If L/R exceeds 7 ms when switching DC inductive loads, an arc-breaking time of up to 50 ms must be considered in application and the circuit must be designed
3. This value is measured at 60 operations/min.
24
50
100/(110)
110
115
200/(220)
220
24
48
100/110
125
200/220
(V)
in this region. Use a contact current of 0.5 A or less when switching 125 VDC or more.
to ensure that an arc-breaking time of 50 ms is not exceeded.
resistance.
Item
Item
245
117
58.5
53
51
29
26.5
94
52
22/24.5
22
11/12
Rated current (mA)
50 Hz
210
102
51/58
46
44
25.5/29
23
Single
Ag
15 A at 220 VAC
10 A at 24 VDC
15 A
250 VAC, 250 VDC
15 A
3,300 VA at 240 W
5 VDC 10 mA
60 Hz
Single
Ag
10 A at 110 VDC
15 A
250 VAC, 250 VDC
15 A
1,200 W at 20 VA
5 VDC at 10 mA
Resistive load
Resistive load
(cosφ = 1)
(cosφ = 1)
8.5
36
150
182
210
620
780
255
930
4,500
5,800
18,000
tance (Ω)
resis-
MM2X(B), MM3X(B), MM4X(B)
Coil
MM2(B), MM3(B), MM4(B)
Open Relays
0.18
0.75
3
3.6
4
12
15
5.6
27.3
61.4
90
158
Open Relays
Coil inductance (H)
Contact
release
7 A at 110 VDC
800 W at 20 VA
(cosφ=0.4, L/R=7 ms)
0.28
1.2
4.5
5.5
6.2
19
21
9.2
45.5
96.5
130
250
Contact
operate
Inductive load
Inductive load
(L/R=7 ms)
80% max. 30% min.
70% max. 10% min.
operate
voltage
Must-
% of rated voltage
(60 Hz)
25% min.
(50 Hz)
7.5 A at 220 VAC
5 A at 24 VDC
7.5 A
250 VAC, 250 VDC
7.5 A
1,700 VA at 120 W
release
voltage
7 A at 110 VDC
800 W at 20 VA
7.5 A
250 VAC, 250 VDC
7.5 A
Must-
Resistive load
Resistive load
MM2P(N, -D), MM3P(N), MM4P(N, -D)
(cosφ = 1)
(cosφ = 1)
110%
MM2XP(-D), MM3XP, MM4XP(-D)
voltage
Max.
Cased Relays
Cased Relays
B
Hot start
after coil
heated
tion level
Opera-
174D)
(JEC-
6 A at 110 VDC
660 W at 20 VA
(cosφ=0.4, L/R=7 ms)
Power consumption
Approx.
6.3
Approx. 2.7
Inductive load
Inductive load
Initial
(L/R=7 ms)
(VA or W)
Approx.
5.1
Rated
MM
5