MM2KP-AC120 Omron, MM2KP-AC120 Datasheet - Page 11

no-image

MM2KP-AC120

Manufacturer Part Number
MM2KP-AC120
Description
RELAY
Manufacturer
Omron
Series
MMKr
Datasheet

Specifications of MM2KP-AC120

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
5A
Switching Voltage
250VAC, 250VDC - Max
Coil Type
Latching, Dual Coil
Coil Current
29.2mA
Coil Voltage
120VAC
Turn On Voltage (max)
96 VAC
Mounting Type
Socket
Termination Style
11 Pin Socketable
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
5A @ 220VAC
Control On Voltage (max)
96 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MM2KPAC120
■ Cased Relays with Plug-in Terminal
Cases on Models for Switching DC Loads
As shown at the right, there are three holes
with a 10-mm diameter in the case.
MM2(X)KP
MM3(X)KP
MM4(X)KP
Terminal Arrangement/
Internal Connections
(Bottom View)
Note: Connect the common (C) to positive (+).
Standard Relays
MM3KP
MM2KP
MM4KP
Make sure that all common connections are the same in polarity. The markings of the common connections on the casing all
show "+" but the polarity of the common connections can be either all negative or all positive.
80.5 max.
Note: It is recommended that 55 mm min. is allowed
80.5 max.
64.5
max.
5
54.5 max. (see note)
for this side because the MM2XKP has a
curved protective plate on the side.
64.5
max.
MM4KP
3.5
22
72.5 max.
(see note)
Case Protective Plate
119 max.
123 max.
7
DC-switching Relays
MM3XKP
Be sure the polarity is
correct when connecting
Exposed Models.
Terminal Arrangement/
Internal Connections
(Bottom View)
Standard Relays
MM2KP
Note: Connect the common (C) to positive (+).
Make sure that all common connections are the
same in polarity. The markings of the common
connections on the casing all show "+" but the
polarity of the common connections can be ei-
ther all negative or all positive.
RESET
SET
Note: It is recommended that 73 mm min.
This example is for the MN2XK.
This also applies to models with 3 or 4 poles.
is allowed for this side because the
MM3XKP and MM4XKP have a
curved protective plate on the side.
MM4XKP
DC-switching Relays
MM2XKP
RESET
SET
MMK
11

Related parts for MM2KP-AC120