G3MC-201PL DC5 Omron, G3MC-201PL DC5 Datasheet - Page 2

SOLID STATE RELAY

G3MC-201PL DC5

Manufacturer Part Number
G3MC-201PL DC5
Description
SOLID STATE RELAY
Manufacturer
Omron
Series
G3MCr
Datasheets

Specifications of G3MC-201PL DC5

Circuit
SPST-NO (1 Form A)
Output Type
AC
Load Current
1A
Voltage - Input
4 ~ 6VDC
Voltage - Load
75 ~ 264 V
Mounting Type
Through Hole
Termination Style
PC Pin
Package / Case
4-SIP
Input Type
DC
Input Voltage (max)
6V
Output Voltage (max)
264V
Output Current
1A
Isolation Voltage
2.5kV
Package Type
SIP
Output Device
Triac
Pin Count
4
Mounting
Through Hole
Operating Temp Range
-30C to 80C
Operating Temperature Classification
Commercial
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G3MC-201PL-DC5
G3MC-201PL-DC5
G3MC201PLDC5
Z2521
Specifications
J RATINGS (AMBIENT TEMPERATURE 25°C)
Input
Note:
Output
J CHARACTERISTICS
Rated voltage
5 VDC
12 VDC
24 VDC
Part number
G3MC-101P(L)
G3MC-201P(L)
G3MC-102P(L)
G3MC-202P(L)
Item
Operate time
Release time
Output ON voltage drop
Leakage current
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Approved standards
Ambient humidity
Weight
2
Each model has 5-VDC, 12-VDC, and 24-VDC input versions.
Solid State Relay
Operating voltage
4 to 6 VDC
9.6 to 14.4 VDC
19.2 to 28.8 VDC
Applicable load
Rated load voltage
100 to 120 VAC
100 to 240 VAC
100 to 120 VAC
100 to 240 VAC
G3MC-101P /
G3MC-102P
1/2 of load power source
cycle + 1 ms
1/2 of load power source cycle + 1 ms)
1.6 V (RMS) max.
1 mA max. (at 100 VAC)
1,000 MΩ min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min
Malfunction: 10 to 55 Hz, 0.75-mm double amplitude
Malfunction: 1,000 m/s
Operating: - -30°C to 80°C (with no icing or condensation)
Storage:
UL508 File No. E64562, CSA C22.2 (No. 14, No. 950) File No. LR35535, EN60950 File No. 5925UG
Operating: 45% to 85%
Approx. 2.5 g
G3MC
- -30°C to 100°C (with no icing or condensation)
2
(approx. 100G)
Impedance
300Ω ±20%
800Ω ±20%
1.6kΩ ±20%
Load voltage range
75 to 132 VAC
75 to 264 VAC
75 to 132 VAC
75 to 264 VAC
G3MC-101PL /
G3MC-102PL
1 ms max.
Voltage levels
Must operate voltage
4 VDC max.
9.6 VDC max.
19.2 VDC max.
Load current
0.1 to 1 A
0.1 to 2 A
G3MC-201P /
G3MC-202P
1/2 of load power source
cycle + 1 ms
1.5 mA max. (at 200 VAC)
Must dropout voltage
1 VDC min.
Surge current
8 A (60 Hz, 1 cycle)
30 A (60 Hz, 1 cycle)
G3MC-201PL /
G3MC-202PL
1 ms max.

Related parts for G3MC-201PL DC5