E2EM-X4B1-M1 Omron, E2EM-X4B1-M1 Datasheet - Page 12

Extnd M12 Shd PNP-NO 4mm M12

E2EM-X4B1-M1

Manufacturer Part Number
E2EM-X4B1-M1
Description
Extnd M12 Shd PNP-NO 4mm M12
Manufacturer
Omron
Type
Inductive Proximity Sensorr
Series
E2EMr
Datasheet

Specifications of E2EM-X4B1-M1

Proximity Sensor Type
Inductive
Output Type
PNP
Proximity Sensor Sensing Distance
4mm
Proximity Sensor Sensing Distance Range
2 to 7mm
Proximity Sensor Switching Mode
NO
Mounting
Panel
Operating Temp Range
-25C to 70C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
10V
Operating Supply Voltage (typ)
12/15/18/24V
Operating Supply Voltage (max)
30V
Pin Count
3
Maximum Operating Temperature
+ 70 C
Operating Supply Voltage
10 V to 40 V
Sensing Distance
4 mm
Minimum Operating Temperature
- 25 C
Features
NO
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
500Hz
Material - Body
Brass
Shielding
Shielded
Voltage - Supply
10 V ~ 40 V
Terminal Type
Connector
Package / Case
Cylinder, Threaded - M12
Lead Free Status / Rohs Status
Compliant
Precautions
J SAFETY PRECAUTIONS
Power Supply
Do not impose an excessive voltage on the E2EM, otherwise it
may be damaged. Do not impose AC current (100 VAC) on any
E2EM DC model, otherwise it may be damaged.
Load Short-circuit
Do not short-circuit the load, or the E2EM may be damaged.
The E2EM’s short-circuit protection function will be valid if the
polarity of the supply voltage imposed is correct and within the
rated voltage range.
Wiring
Be sure to wire the E2EM and load correctly, otherwise it may be
damaged.
Connection with No Load
Be sure to insert loads when wiring. Make sure to connect a
proper load to the E2EM in operation, otherwise it may damage
internal elements.
Do not expose the product to flammable or explosive
gases.
Do not disassemble, repair, or modify the product.
J CORRECT USE
Designing
Power Reset Time
The Proximity Sensor is ready to operate within 100 ms after
power is supplied. If power supplies are connected to the
Proximity Sensor and load respectively, be sure to supply power
to the Proximity Sensor before supplying power to the load.
E2EM
13
Effects of Surrounding Metal
When mounting the E2EM within a metal panel, ensure that the
clearances given in the following table are maintained.
(Unit: mm) See note.
Note: To convert mm to inches, multiply mm’s by 0.03937.
Power OFF
The Proximity Sensor may output a pulse signal when it is turned
OFF. Therefore, it is recommended that the load be turned OFF
before turning OFF the Proximity Sensor.
Power Supply Transformer
When using a DC power supply, make sure that the DC power
supply has an insulated transformer. Do not use a DC power
supply with an auto-transformer.
AND/OR Connection
When using the product in an AND/OR circuit, the product may
not function properly due to incorrect pulses or leakage currents.
Therefore, confirm that no problems will occur before actually
using the product in such a circuit.
E2EM-
E2EM
XjXj
DC 2 wire
DC 2-wire
E2EM-
E2EM
XjBj/Cj
DC 3 wire
DC 3-wire
Type
Shielded
Shielded
Unshielded
Unshielded
Shielded
Shielded
d
D
m
n
d
D
m
n
d
D
m
n
Item
d dia.
---
---
0
8
0
4.5
12
M8
2.4
18
2.4
12
18
---
2.4
18
2.4
12
18
M12
3.6
27
3.6
24
27
25
70
25
48
70
3.6
27
3.6
24
27
M18
E2EM
6
45
6
45
45
45
120
45
90
120
6
45
6
45
45
M30

Related parts for E2EM-X4B1-M1