E2C-X2A Omron, E2C-X2A Datasheet - Page 15

SEP.AMP.PROX. M12, 5mm DIST

E2C-X2A

Manufacturer Part Number
E2C-X2A
Description
SEP.AMP.PROX. M12, 5mm DIST
Manufacturer
Omron
Series
E2Cr
Type
Inductive Proximity Sensorr
Datasheets

Specifications of E2C-X2A

Maximum Operating Temperature
+ 70 C
Supply Voltage
30 V
Sensing Distance
2 mm
Minimum Operating Temperature
- 25 C
Features
Adjustable
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
800Hz
Material - Body
Brass
Shielding
Shielded
Voltage - Supply
-
Output Type
-
Terminal Type
2-Wire
Package / Case
Cylinder, Threaded - M12
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use the Encoder under ambient conditions that exceed the
ratings.
● Design
Influence of Surrounding Metal
When mounting the Sensor within a metal panel, ensure that the
clearances given in the following table are maintained. Failure to
maintain these distances may cause deterioration in the performance
of the Sensor.
Influence of Surrounding Metal
Note: Values in parentheses for diameter d are the outer diameters of Shielded
Mutual Interference
When installing Sensors face-to-face or side-by-side, ensure that the
minimum distances given in the following table are maintained.
Mutual interference can be prevented by using the cable length
compensation switch, but doing so will also change coil
characteristics. Specifications such as temperature specifications
and sensing distance, may not be sufficiently met, so always check
operation before actual application.
This method cannot be used for the E2C-G@4A, E2C-JC4A, E2C-
C20MA.
Mutual Interference
Note: The above values are for a differential travel setting of 5%.
Model
E2C-CR8
E2C-X1A
E2C-C1A
E2C-X1R5A(H)
E2C-X2A(H)
E2C-X5A(H)
E2C-X10A
E2C-C20MA
Model
E2C-CR8
E2C-X1A
E2C-C1A
E2C-X1R5A(H)
E2C-X2A(H)
E2C-X5A(H)
E2C-X10A
E2C-C20MA
Models.
Precautions for Correct Use
Distance
Distance
l
(Unit: mm)
A
m
25
100
300
0
20
30
50
l
A
WARNING
(3.5)
(5.4)
(12)
(18)
(30)
120
(5)
(8)
200
d
15
20
35
70
B
B
40
D
D
0
(Unit: mm)
d dia.
2.4
4.5
15
30
60
m
3
6
Mounting
Note: The above leeways in tighten torque assume that a toothed washer is
• Do not use excessive force when tightening the nuts on the E2C-X
E2C-X1A
E2C-X1R5A(H)
E2C-X2A(H)
E2C-X5A(H)
E2C-X10A
E2C-C20MA
• Mounting Unthreaded Cylindrical Models
and E2C-C20MA. A washer must be used with the nut.
When using a set screw, tighten it to a torque of 0.2 N·m max.
Dimpled end of
set screw (M3)
being used.
Model
7 to 11.5 mm
0.98 N·m
2.0 N·m
5.9 N·m
Torque
15 N·m
39 N·m
15 N·m
Y92E-F3R5 Mounting Bracket
(for 3.5 dia.) (Order Separately)
The Y92E-F5R4 (for 5.4 dia.)
is also sold separately.
E2C/E2C-H
15