DRT2-OD32BV-1 Omron, DRT2-OD32BV-1 Datasheet - Page 324
DRT2-OD32BV-1
Manufacturer Part Number
DRT2-OD32BV-1
Description
32 Out Vert MIL Connector PNP
Manufacturer
Omron
Datasheet
1.DRT2-OD16.pdf
(600 pages)
Specifications of DRT2-OD32BV-1
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
- Current page: 324 of 600
- Download datasheet (13Mb)
7-1-7
Overview of Analog Slaves
Fixed allocations
User allocations
Allocated area in
Master
Allocating I/O Data in the Master
Allocation method
1.
2.
Note Settings from the Master are
1.
2.
3.
Note Supported
Default I/O data allocation
Using Configurator to select I/O data
(patterns) by editing the Slave’s de-
vice parameters (fixed I/O data com-
binations)
Default I/O data allocation
Using Configurator to select I/O data
(patterns) by editing the Slave’s de-
vice parameters (fixed I/O data com-
binations)
Using Configurator to select I/O data
for each connection by editing the
Master’s device parameters and al-
locating each data to user-defined
addresses (user-defined I/O data
combinations)
Note For details on the data allocation patterns and methods, refer to 7-4-2 I/O
supported
DeviceNet Units only.
DeviceNet Units only.
Allocated I/O data
I/O is allocated in the Master using the methods shown in the following table.
Select the appropriate method depending on whether the allocated area in
the Master is fixed or user-defined, and whether the allocated I/O data is the
default I/O, a selected combination of data, or user-defined data.
Data Allocation Methods.
by
by
CJ/CS-series
CJ/CS-series
Allocates only analog/temperature input values for 4
points.
The following 11 types of I/O data can be allocated by
selecting from the pull-down menu for the Slave’s default
connection path.
• Analog Data 1 or Temperature Data 1
• Analog Data 2 or Temperature Data 2
• Generic Status Flags
• Top/Valley Detection Timing Flags
• Analog Status Flags
• Analog Data 1 + Analog Data 2 or Temperature Data 1
• Top/Valley Detection Timing Flags + Generic Status
• Analog Status Flags + Generic Status Flags (5 input
• Analog Data 1 or Temperature Data 1 + Top/Valley
• Analog Data 1 or Temperature Data 1 + Top/Valley
• Hold Flags
(Same as fixed allocations.)
(Same as fixed allocations.)
The following 11 types of I/O data can be allocated by
selecting up to two types from the pull-down menu for
the Master’s connection path.
• Analog Data 1 or Temperature Data 1
• Analog Data 2 or Temperature Data 2
• Generic Status Flags
• Top/Valley Detection Timing Flags
• Analog Status Flags
• Analog Data 1 + Analog Data 2
• Top/Valley Detection Timing Flags + Generic Status
• Analog Status Flags + Generic Status Flags
• Analog Data 1 or Temperature Data 1 + Top/Valley
• Analog Data 1 or Temperature Data 1 + Top/Valley
• Hold Flags
+ Temperature Data 2
Flags
bytes)
Detection Timing Flags
Detection Timing Flags + Generic Status Flags
Flags
Detection Timing Flags
Detection Timing Flags + Generic Status Flags
I/O data that can be allocated in the Master
Section 7-1
303
Related parts for DRT2-OD32BV-1
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
DRT2 Mix IO E-Con 8in/out PNP
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
DRT2 16 OutMIL Conn Cable With
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
DRT2 16 In MIL Connector NPN
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
DRT2 16 In MIL Connector PNP
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
DRT2 16 In MIL Conn Cable With
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
DRT2 16 In MIL Conn Cable With
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
DRT2 Mix IO E-Con8 In/out, NPN
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
DRT2 8 Out TermOutal NPN
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: