D4F-202-3R Omron, D4F-202-3R Datasheet
D4F-202-3R
Specifications of D4F-202-3R
Related parts for D4F-202-3R
D4F-202-3R Summary of contents
Page 1
... D4F-120-1R D4F-220-1R D4F-120-1D D4F-220-1D D4F-120-3R D4F-220-3R D4F-120-3D D4F-220-3D D4F-120-5R D4F-220-5R D4F-120-5D D4F-220-5D D4F-102-1R D4F-202-1R D4F-102-1D D4F-202-1D D4F-102-3R D4F-202-3R D4F-102-3D D4F-202-3D D4F-102-5R D4F-202-5R D4F-102-5D D4F-202-5D CSM_D4F_DS_E_3_1 models with safety standard certification. 2NC/2NO 4NC (slow-action) (slow-action) Direct Model Model opening D4F-320-1R D4F-420-1R ...
Page 2
... UL/CSA (UL508, CSA C22.2 No. 14) C300 Rated Carry current voltage File No. 120 VAC 2 240 VAC Q300 E76675 Rated 20030103050 Carry current voltage 64266 125 VDC 2.5 A 250 VDC D4F AC-15 DC-13 ) 0. 240 V 250 V e Current (A) Volt-amperes (VA) Make Break Make Break 15 1.5 1,800 180 7 ...
Page 3
... Hz, 0.75 mm single amplitude 2 1,000 m/s min. 2 300 m/s min. 100 A (EN60947-5-1) 2.5 A (EN60947-5-1) −30 to 70°C (with no icing) 95% max. UL2464 No. 22 AWG, finishing O.D.: 8.3 mm Approx. 190 g (D4F-102-1R, with 1 m cable) Approx. 220 g (D4F-120-1R, with 1 m cable) D4F 3 ...
Page 4
... Zb 11-12 12 21-22 22 31-32 41-42 32 Stroke 42 D4F Head The plunger type of actuator can be used in a normal direction and reverse direction. Cable The cable can be pulled out in a horizontal direction vertical direction. Remarks Only NC contact 11-12 has a certified direct opening mechanism. ON The terminals 11-12 and 33-34 can be used as unlike poles ...
Page 5
... The OF value is the maximum load that opens an NC contact (11-12, 21-22, 31-32, 41-42). *2. The RF value is the minimum load that closes an NC contact (11-12, 21-22, 31-32, 41-42). *3. The PT2 and TT values are reference values. *4. The D4F is used in accordance with EN81 and EN115 at a minimum DOT of 30° and 2.8 mm. Roller plunger (Metal roller) D4F-@02-@R (30 ...
Page 6
... Lever mounting screw (M5) 2.4 to 2.8 N·m 2 Body mounting screw (M4) 1.18 to 1.37 N· Mounting Use two M4 screws and washers to mount the D4F securely. The D4F can be mounted more securely with proper tightening torque. Mounting Holes (Unit: mm) Two, 4.2-dia screw hole 20± 0.1 Changing the Lever Angle • ...
Page 7
... Terminal Numbers • Identify terminal numbers based on the color (with or without white lines) of the insulation on the wire. • The safety and auxiliary contacts of D4F models of four-terminal contact construction and those of two-terminal contact construction are described below. • The safety contacts are direct-opening NC contacts (11-12 and 21- 22) ...
Page 8
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...