61F-GP-N8-V50 AC110 Omron, 61F-GP-N8-V50 AC110 Datasheet - Page 48

no-image

61F-GP-N8-V50 AC110

Manufacturer Part Number
61F-GP-N8-V50 AC110
Description
LEVEL CONTROLLER
Manufacturer
Omron
Series
61Fr
Type
Level Control - Variable Sensitivityr
Datasheets

Specifications of 61F-GP-N8-V50 AC110

Applications
Supply and Drain Control
Mounting Type
Socket Mount (8 pos)
Voltage - Supply
110VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
61F-GP-N8-V50AC110
61FGPN8V50AC110
Mounting
61F
Other Accessories
Note: 1. OMRON does not sell couplings.
Use this Cover for PS-series Electrode
Holders with Mounting Frames (upper one
in the following illustration), This Cover can
also be used when installing the BF-series
Electrode Holders outdoors. Since this
Cover is not water-proof, water or dust may
enter through the wire hole (lower one
below).
Applicable Electrode Holders:
BF-3, BF-4, BF-5, PS-3S(R), PS-4S(R),
PS-5S(R)
1. Mounting Electrode Holder
PS-3S Electrode Holders
Two, M5 x 25
mounting screws
Twin
clockwise
Screw the Electrode Holder into the
coupling secured at the installation
location.
2. Screw in the Electrode until it reaches the bottom of the nut. Insufficient insertion will cause a faulty connection.
60
F03-11 Protective Cover
Coupling
Electrode
120 dia.
Weight:
approx. 65g
Operating
temp.: --10°C
to 70°C
Electrode
Holder
Used to clamp an Electrode Holder with
ease, as shown in the illustrations, when
the Electrode Holder is applied to a tank
without a coupling.
Squeeze the mounting frame into the
Holder as shown below.
Applicable Electrode Holders:
PS-3S(R), PS-4S(R), PS-5S
2. Attaching Electrode(s) to Electrode
section
Four, M5 x 25
mounting
screws
Insert each Electrode into the connecting
nut, secure the Electrode with the clamp
screws, and then tighten the lock nut.
Connect the leads, inserted through the
hole of the rubber bushing, into the
respective terminals.
Electrode section
housing
10
Lock nut
F03-12 Spring Clamp
Electrode
112 dia.
96
Rubber
bushing
Electrode
Useful frame for burying in concrete. Cut
as required based on the concrete depth.
Mounting Frame em-
bedded into concrete
3. Inserting Electrode section into
Electrode Holder
F03-13 Mounting Frame for installing in
100
Commonly used with
Mounting Frame
Fit the Electrode section into the
Electrode Holder and secure it with the
two screws.
Check the Electrode section for proper
wiring, fit the rubber bushing in position,
and then cover the Electrode Holder with
the drip-proof cover.
Electrode
Holder
80
Electrode
section
housing
Drip-proof
cover
60
115 dia.
72 dia.
82 dia.
concrete
96
Electrode
70
61F