1VAP2-1 Omron, 1VAP2-1 Datasheet - Page 3

no-image

1VAP2-1

Manufacturer Part Number
1VAP2-1
Description
SWITCH
Manufacturer
Omron
Series
1VAP2r
Datasheet

Specifications of 1VAP2-1

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
15A @ 125VAC
Actuator Type
Push-Pull Plunger
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
1760gf
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
1VAP21
Safety Precautions
Refer to Safety Precautions for All Basic Switches.
Mounting Holes
Wiring
Tighten the terminal screws to the torque given in the following table.
Operating Environment
• The Switch does not have a water-resistant structure. Take
• Do not use the Switch where it is continuously subjected to vibration
• Do not use the Switch in locations subject to corrosive gas, such as
• If the Switch is used in locations with silicone gas, arc energy may
• Use the switch within the specified range for operating temperature
Front mounting
Side mounting
measures to protect the Switch if it is to be used in locations subject
to splashing or spraying water or other liquids.
or shock. Doing so will result in contact failure, malfunction, or a
decrease in service life caused by abrasive powder that is
generated from the internal parts. Subjecting the Switch to
excessive vibration or shock may cause the contacts to
malfunction, stick, or become damaged. Make sure to install the
Switch in locations free of vibration or shock or in a direction where
resonance will not occur.
sulfuric gas (H
or chlorine gas (Cl
Doing so will result in damage due to contact failure or corrosion.
cause silicon dioxide (SiO
failure may result. If there is silicone oil, silicone sealant, or wire
covered with silicone close to the Switch, attach a contact
protective circuit to suppress the arcing of the Switch or eliminate
the source of silicone gas.
and humidity. Using the Switch in high temperatures will cause the
operating characteristics to deviate. Rapid changes in temperature
will also cause the operating characteristics to deviate. It is
recommended to install the Switch as far as possible from heat
sources so that the temperature of the Switch is not affected.
Mounting
direction
0.78 to 1.78 N·m
1ZAP2
Precautions for Correct Use
2
S or SO
2
), or high temperature and humidity.
2
), ammonium gas (NH
Two, 4.5
2
Two, 4.5
) to build up on the contacts and contact
1ZAP2
25.4
10 dia. min.
11.1
11.1
± 0.3
+0.3
0
+0.3
± 0.3
± 0.3
dia. holes
0
0.39 to 0.49 N·m
dia. holes
1VAP2
3
), nitric gas (HNO
Two, 4
1VAP2-1
Two, 4
20.6
10.3
12.7
10 dia. min.
+0.3
0
±0.3
dia. holes
+0.3
± 0.3
± 0.3
3
0
),
dia. holes
Two, 3.5
Two, 3.5
1VAP2-2
19.1
10 dia. min.
38.1
± 0.3
± 0.3
8.7
± 0.3
+0.3
38.1
+0.3
0
0
dia. holes
dia. holes
± 0.3
1ZAP2/1VAP2
(Side mounting is not possible)
Four, M4 or 4.5
37
1VAP2-6
± 0.3
+0.3
0
dia. holes
58
± 0.3
3

Related parts for 1VAP2-1