S8VM-30005C Omron, S8VM-30005C Datasheet - Page 12

60A,5V,btm Mt,Cov, 300W

S8VM-30005C

Manufacturer Part Number
S8VM-30005C
Description
60A,5V,btm Mt,Cov, 300W
Manufacturer
Omron
Series
S8VMr
Datasheet

Specifications of S8VM-30005C

Voltage - Output
5V
Number Of Outputs
1
Power (watts)
300W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 60A
2nd Output
-
3rd Output
-
4th Output
-
Size / Dimension
7.40" L x 3.29" W x 2.46" H (188mm x 83.5mm x 62.5mm)
Operating Temperature
-10°C ~ 70°C
Power (watts) - Max
300W
Efficiency
77%
Approvals
CSA, cUL, EN, UL
Line Regulation
-
Load Regulation
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
■ Probable Causes of Power Supply Errors and Troubleshooting Using
Check the following information if the Undervoltage Alarm Function operates.
Contact your OMRON representative if the Power Supply does not function normally after checking.
The symbols in the table are as follows:
Note: Flashing: The output voltage is unstable, causing the LED to repeatedly turn ON and OFF.
12
1
2
3
4
5
6
7
8
: Lit,
Undervoltage Alarm Function
LED D:
DC ON
Green
: Not lit,
Switch Mode Power Supply
LED F:
Yellow
DC LOW1
: Flashing
Transistor
( H to J )
outputs
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
LED G:
Red
DC LOW2
Transistor
( I to J )
outputs
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
S8VM
→ No output
→ Unstable output
Normal
(approx. 90% min.
of rated output
voltage)
Normal
(approx. 90% min.
of rated output
voltage)
Output drop
(approx. 90%
max. of rated
output voltage)
Output drop
(approx. 90%
max. of rated
output voltage)
Output drop
(approx. 80% of
rated output
voltage)
Output drop
(approx. 80% of
rated output
voltage)
Output voltage
Normal status
The output voltage has re-
covered to normal status
following a previous sud-
den voltage drop.
The output voltage has
dropped gradually and re-
mains low.
The output voltage re-
mains low following a pre-
vious sudden voltage
drop.
The output voltage re-
mains low and is continu-
ing to fluctuate following a
previous sudden voltage
drop.
The output voltage has
dropped gradually, re-
mains low, and is continu-
ing to fluctuate.
No output voltage is being
output.
The output voltage is un-
stable.
Power Supply status diagnosis
24 V
24 V
24 V
24 V
24 V
24 V
24 V

Related parts for S8VM-30005C