G5SB-14 DC9 Omron, G5SB-14 DC9 Datasheet - Page 39

POWER PCB RELAY

G5SB-14 DC9

Manufacturer Part Number
G5SB-14 DC9
Description
POWER PCB RELAY
Manufacturer
Omron
Series
G5SBr
Datasheets

Specifications of G5SB-14 DC9

Relay Type
General Purpose
Contact Form
SPDT (1 Form C)
Contact Rating (current)
5A
Switching Voltage
250VAC, 30VDC - Max
Coil Type
Standard
Coil Current
44.4mA
Coil Voltage
9VDC
Turn On Voltage (max)
6.75 VDC
Turn Off Voltage (min)
0.45 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
5A @ 125VAC
Control On Voltage (max)
6.75 VDC
Control Off Voltage (min)
0.45 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G5SB-14-DC9
G5SB14DC9
Z1641
36
Micro Sensors - MEMS
Mass Air Flow 10~50L
Mass Air Flow 1~5L
Operating temp. range
Air Velocity Sensor
Ordering information
Dimensions mm (in)
Applicable gases
Supply voltage
Output voltage
Features
Operating temp. range
Operating temp. range
*Contact Omron regarding other gases.
9H x 20Dx 39L
(0.35 x 0.79 x 1.53
• Clogged filter detection
• Compact size
• Integral passive Dust Segregation
• Fast fit for easy installation
Air*
12 - 24VDC
5VDC
-10° to +60°C
Flow range
0~1 m/sec flow range D6F-WO1A
0~4 m/sec flow range D6F-WO4A
Ordering information
Ordering information
Dimensions mm (in)
Dimensions mm (in)
System (DSS)
Applicable gases
Applicable gases
Supply voltage
Supply voltage
Features
Features
D6F-W
Part number
15H x 20D x 66W
(0.60 x 0.79 x 2.60)
Detects –
• Breath rate in respiratory equipment
• Natural gas flow rate
• Gas in fuel cells
• Flow in ventilation systems
Air, Natural gas, LP gas, O
12 to 24VDC
-10 ° to +60°C
*Contact Omron regarding other gases.
Case Gas Flow range Part number
PPS
PPS
AL
30H x 30D x 78L
(1.18 x 1.18 x 3.07)
• Precision unidirectional mass airflow up to 50LPM
• Stable output
• Horizontal mounting with NBR ‘O’ ring
• Low power consumption
Air, Natural gas, LP gas, O
12 to 24VDC
-10 ° to +60°C
Flow range
0-10LPM
0-20LPM
0-50LPM
*Contact Omron regarding other gases.
Air
Air
LNG 0~5L/min
D6F-10/20/50
0~1L/min
0~2L/min
8H x 13D x 24L
(0.31 x 0.51 x 0.94)
• Value engineered version of D6F-W
• Smaller package
• Lower Supply Voltage
• Built for OEM designs
• Internal passive Dust Segregation
Air*
3.3VDC
0 to 2VDC
-10° to +60°C
Flow range
0~3 m/sec flow range D6F-V03A1
System (DSS)
Part number
D6F10A600
D6F20A600
D6F50A600
D6F
2
2
D6F-V
, and N
, & N
D6F-101A-110
D6F-102A-110
D6F-05N2-000
2
O*
2
O *
Part number

Related parts for G5SB-14 DC9