EE-SX914P-R 1M Omron, EE-SX914P-R 1M Datasheet
EE-SX914P-R 1M
Specifications of EE-SX914P-R 1M
Related parts for EE-SX914P-R 1M
EE-SX914P-R 1M Summary of contents
Page 1
... Indicator Visible from Many Directions for Installation in Any Location The light indicator can be checked from up to four directions. Mount Using Screws The EE-SX91 can be mounted using screws can Load 1 easily replace an existing compact sensor mounted with M2 screws. Load ...
Page 2
... Prewired models with a 3-m cable are also available. When ordering, specify the cable length by adding “3M” for the end of the model number (e.g., EE-SX910-R 3M). Connecting Output Indicator method configuration mode (Cable length) Light-ON Lit when light Pre-wired models Dark-ON is incident ( outputs) EE-SX91 Infrared light Model NPN output PNP output EE-SX910 EE-SX910P EE-SX911 EE-SX911P EE-SX912 EE-SX912P EE-SX913 EE-SX913P EE-SX914 EE-SX914P ...
Page 3
... Storage 2,000 Hz (peak acceleration: 150m/s Vibration resistance (Destruction) 0.75-mm single amplitude for 2.5 h (15-min periods, 10 cycles) each and Z directions Shock resistance (Destruction) 500 m/s Degree of protection IEC60529 IP50 Connecting method Pre-wired Models (standard cable length Weight Pre-wired Models Approx (packed state) ...
Page 4
... Engineering Data (Typical) Sensing Position Characteristics EE-SX910 Dark-ON d Insertion direction Light- Distance d (mm) Repeated Sensing Position Characteristics EE-SX910 Dark-ON d=±0.002 d Light-ON 3.14 3.16 3.18 Distance d (mm) Vcc = 24 V, No. of repetitions: 20 25°C (Differential distance = 0.025 mm max.) Note: The data applies to dark status. Operation may be affected by external light interference or light coming through the sensing object ...
Page 5
... Output Output transistor Model type operation status EE-SX910-R EE-SX911-R NPN EE-SX912-R output EE-SX913-R EE-SX914-R OUT1: Light-ON OUT2: Dark-ON EE-SX910P-R EE-SX911P-R PNP EE-SX912P-R output EE-SX913P-R EE-SX914P-R Timing charts Light incident Light interrupted Light indicator (orange) Light indicator ON Main (orange) circuit OFF ON Output 1 ...
Page 6
... Blue Precautions for Correct Use ● Installation • assumed that EE-SX91 Sensors will be built into a device. These Sensors use non-modulated light and are not equipped to deal with interference from an external light source. When they are used in locations subject to external light interference, such as near a window or under an incandescent light, install them to minimize the effects of external light interference ...
Page 7
... If the electric power of the output transistor increases due to a load short-circuit or near load short-circuit, the Sensor may be damaged. • An output pulse may occur when the power supply is turned ON depending on the power supply and other conditions. The operation of the Sensor will be stable 100 ms after turning ON the power supply. EE-SX91 7 ...
Page 8
... Indicator window 8 Two, 3.2 dia. EE-SX914-R Robot cable of 2.8 dia., 4 cores, 2 (0.15 mm with 0.8-mm dia. insulator); Standard length Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified. EE-SX911-R EE-SX911P-R 1.75 1.6 5.8 0.8 1.2 (Four, R1.6) Sensing window 6.9 6 ...
Page 9
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...