Specifications of D4N-112G

Actuator Style
Adjustable Roller Lever
Operating Force Max
4.5N
Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
10A
Contact Current Dc Max
2.5A
Rohs Compliant
Yes
Lead Free Status / Rohs Status
 Details
1-conduit Models
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
* Refer to page 12 for details on M12 connectors.
Plunger
D4N-1@31
D4N-3@31
D4N-9@31 *
One-way Roller Arm Lever
(Horizontal)
D4N-1@62
D4N-3@62
D4N-9@62 *
2.15±0.05R
mounting holes
OP
OP
55
23.3
47
9
±0.2
± 0.2
19.5
13.5
11
2.5
±0.2
±0.2
Operating direction
31 max.
14.8
31 max.
20
22
22
D4N-2@31
D4N-4@31
D4N-2@62
D4N-4@62
25
20
22
22
±
±
±
±0.1
± 0.1
± 0.1
± 0.2
0.1
0.1
0.2
6-dia. resin
plunger
12 dia.
20R
12.5 dia. × 5
resin roller
Two, 3±0.05 dia.
holes
2.15±0.05R
mounting holes
2.5
Conduit cap
Conduit cap
47
9
±0.2
±
0.2
55
(31.5)
(31.5)
11
30
21.5
30
11
21.5
14.2
14.2
±0.2
±0.2
10.2
Two, 4
Depth: 5
Two, 4
Depth: 5
+0.15
0
+0.15
0
dia. holes
dia. holes
Roller Plunger
D4N-1@32
D4N-3@32
D4N-9@32 *
One-way Roller Arm Lever
(Vertical)
D4N-1@72
D4N-3@72
D4N-9@72 *
OP
55
55
47
47
9
9
±0.2
± 0.2
±0.2
±
0.2
2.5
2.5
11
20.5 × 20.5
±0.2
31 max.
31 max.
D4N-2@32
D4N-4@32
D4N-2@72
D4N-4@72
22
20
22
22
20
22
± 0.1
± 0.1
± 0.2
±
±
±
0.1
0.1
0.2
OP
12
9.5 dia. × 5
resin roller
2.15±0.05R
mounting holes
2.15±0.05R
mounting holes
25.2
Operating
direction
Conduit cap
Conduit cap
12 dia. × 5
resin roller
19R
19.5
14.7
±0.2
(31.5)
(31.5)
30
11
21.5
30
11
21.5
14.2
14.2
±0.2
±0.2
10.2
Two, 4
Depth: 5
Two, 4
Depth: 5
+0.15
+0.15
0
0
dia. holes
dia. holes
D4N
10