D4B-2115N-KGM1 Omron, D4B-2115N-KGM1 Datasheet - Page 4

no-image

D4B-2115N-KGM1

Manufacturer Part Number
D4B-2115N-KGM1
Description
LS, G1/2, SPDT, Rlrlev
Manufacturer
Omron
Datasheet

Specifications of D4B-2115N-KGM1

Actuator Style
Roller Lever
Contact Voltage Ac Max
600V
Contact Current Ac Max
10A
Rohs Compliant
Yes
J UL/CSA: (UL508, CSA C22.2 NO. 14)
A600
Q150
Rating Codes for DC Control-Circuit Contacts
J CHARACTERISTICS
Note: 1. The above values are for initial operation.
Rated voltage
120 VAC
240 VAC
480 VAC
600 VAC
Thermal continuous
test current
test current,
amperes
2.5
Item
Life expectancy
(
(see note 2)
Operating speed
Operating frequency
Rated frequency
Insulation resistance
Contact resistance
Dielectric strength
Rated insulation voltage (U
Counter electromotive voltage at switching 1,500 VAC max. (EN60947-5-1)
Operating environmental pollution level
Conditional short-circuit current
Conventional enclosed thermal current
(I
Electric shock protection class
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Degree of protection
Weight
the
)
Between terminals of same polarity
Between terminals of different polarity
Between current-carrying metal parts
and ground
Between each terminal and
non-current-carrying parts
2. The life expectancy is for an ambient temperature of 5°C to 35°C and ambient humidity of 40% to 70%. For further conditions,
3. The values in this table are for an ambient temperature of 5°C to 35°C and ambient humidity of 40% to 70%. For further condi-
p
consult your OMRON sales representative.
tions, consult your OMRON sales representative.
2)
g
y
Maximum make or break current, amperes
125 Volt
0.55
Carry current
C
10 A
Mechanical
Electrical
y
i
)
Snap-action
30,000,000 operations min.
500,000 operations min. (at a 250 VAC, 10-A resistive load)
1 mm/s to 0.5 m/s
Mechanical: 120 operations/min
Electrical:
50/60 Hz
100 MΩ min. (at 500 VDC) between terminals of the same polarity and between each
terminal and non-current-carrying part
25 mΩ max. (initial value)
U
U
U
600 VAC (EN60947-5-1)
3 (EN60947-5-1)
100 A (EN60947-5-1)
20 A (EN60947-5-1)
Class I (with grounding terminal)
Malfunction: 10 to 55 Hz, 0.75 mm single amplitude
Destruction: 1,000 m/s
Malfunction:300 m/s
Operating: --40°C to 80°C, with no icing (--25°C to 80°C for the flexible-rod type)
Operating: 95% max.
IP67 (EN60947-5-1)
Approx. 250 g
---
Current
Make
60 A
30 A
15 A
12 A
250 Volt
imp
imp
imp
2.5 kV
4 kV
4 kV
30 operations/min
2
min.
2
5
Break
6 A
3 A
1.5 A
1.2 A
301 to 600 Volt
min.
Slow-action
10,000,000 operations min.
U
U
U
U
Volt-amperes
Make
7,200 VA
Maximum make or break volt-amperes at
300 volts or less
300 volts or less
69
imp
imp
imp
imp
4 kV
4 kV
4 kV
4 kV
Break
720 VA
D4B-N

Related parts for D4B-2115N-KGM1