CGT-12M-6.0 CARLO GAVAZZI, CGT-12M-6.0 Datasheet

TOR 12M 4-6

CGT-12M-6.0

Manufacturer Part Number
CGT-12M-6.0
Description
TOR 12M 4-6
Manufacturer
CARLO GAVAZZI
Datasheet

Specifications of CGT-12M-6.0

Overload Adjustment Current Min
4A
Overload Adjustment Current Max
6A
External Width
44mm
External Depth
63.7mm
Mounting Type
DIN Rail
External Height
73.2mm
Approval Bodies
CE, UL, CUL
Mini overload relays
Bimetallic style
Certificate
CE, UL
AZ-12H
Separate
mount
CGT-12M
C
UL
CGMS-6~16
CGT-12M
Direct
mount
Description
- Direct mount on the mini contactors with screw clamp connection.
- DIN rail or screw mountable with the optional base AZ-12H
- Small physical size : 44 mm wide
- 1NO+1NC trip contacts
- Trip class 10A according to IEC60947-4-1
- Differential current/Phase failure protection : CGT types
- Non-differential CGTH types are available for the economic solution
- Ambient compensated -5 to 40
- Manual/Automatic reset convertible.
- Remote reset is optional
- Trip free designed
Catalog No.
Auxiliary (Trip) contact rating
Note)
For more information
Drawings
Mini Contactors
Starters
Separate mounting unit
Operating curves
Setting ranges(A)
contactor types : CGMS-6A(D), CGMS-9A(D),
0.16
0.25
0.63
Values of (
0.1
0.4
1.6
2.5
2.5(0.3)A
12
1
4
5
6
7
9
110V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.16
0.25
0.4
0.63
1
1.6
2.5
4
6
8
9
10
13
16
) are the ratings of NO contact under auto reset mode.
CGMS-12A(D), CGMS-16A(D)
AC15(11) duty
2(0.3)A
220V
Differential type
3-heater
CGT-12M 0.16
CGT--12M 0.25
CGT--12M 0.4
CGT--12M 0.63
CGT--12M 1
CGT--12M 1.6
CGT--12M 2.5
CGT--12M 4
CGT--12M 6
CGT--12M 8
CGT--12M 9
CGT--12M 10
CGT--12M 13
CGT--12M 16
page 37
page 18~26
page 32
page 33
page 39
1(0.3)A
550V
CGTH-12MH/3 0.16
CGTH-12MH/3 0.25
CGTH-12MH/3 0.4
CGTH-12MH/3 0.63
CGTH-12MH/3 1
CGTH-12MH/3 1.6
CGTH-12MH/3 2.5
CGTH-12MH/3 4
CGTH-12MH/3 6
CGTH-12MH/3 8
CGTH-12MH/3 9
CGTH-12MH/3 10
CGTH-12MH/3 13
CGTH-12MH/3 16
3-heater
Non-differential type
0.28A
110V
DC13(11) duty
CGTH-12MH 0.16
CGTH-12MH 0.25
CGTH-12MH 0.4
CGTH-12MH 0.63
CGTH-12MH 1
CGTH-12MH 1.6
CGTH-12MH 2.5
CGTH-12MH 4
CGTH-12MH 6
CGTH-12MH 8
CGTH-12MH 9
CGTH-12MH 10
CGTH-12MH 13
CGTH-12MH 16
2-heater
0.14A
220V
27

Related parts for CGT-12M-6.0

CGT-12M-6.0 Summary of contents

Page 1

... DIN rail or screw mountable with the optional base AZ-12H - Small physical size : 44 mm wide - 1NO+1NC trip contacts - Trip class 10A according to IEC60947-4-1 - Differential current/Phase failure protection : CGT types - Non-differential CGTH types are available for the economic solution - Ambient compensated - CGT-12M - Manual/Automatic reset convertible. - Remote reset is optional - Trip free designed Catalog No ...

Page 2

... CGT(H)-12M 45 8.1 8.8 ‹ 1.6 M3.5 (Main terminal) 10 M3.5 (Main terminal) 10.6 CGT(H)-12MH 45 7.6 8.7 M3.5 (Main terminal) M3.5 (Aux. terminal) 10 M3.5 (Main terminal) 10.6 CGMSS-6,9, 45 7.6 12,16A M3.5 (Main terminal) M3.5 (Main terminal) M3.5 (Aux. terminal) 10 M3.5 (Main terminal) 10 ...

Page 3

... Overload relay curves Non-Differential type CGTH-12M Cold state 0.8 0.6 0.5 0.4 0 Multiple of current setting Differential type CGT-12M Cold state Open-phase 10 80 (Average 0.8 0.6 0.5 0.4 0 Multiple of current setting 0.8 0.6 0.5 0 0.8 0.6 0.5 0.4 0 (A) Hot state ...

Related keywords