A22Z-EG1 Omron, A22Z-EG1 Datasheet - Page 18

no-image

A22Z-EG1

Manufacturer Part Number
A22Z-EG1
Description
FlushmntE-StopShroudSetForSEMI
Manufacturer
Omron
Series
A22Er
Type
E-Stop Shroudr
Datasheets

Specifications of A22Z-EG1

Color
Yellow
Illumination
Not Illuminated
Length
90 mm
Mounting Style
Panel
Width
75 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
A22E Emergency Stop Switches
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Control Box (Enclosure)
Installing/Removing the Switch Blocks
The Standard-size Legend Plate Frame can be mounted. Mount the Frame as
shown in the following diagram. Mount the Switch in the same way as for an
ordinary panel.
1. Insert the connector into the cable port hole in the Box and secure with the fixing nut inside the box.
2. Open a hole in the thin rubber section of the rubber ring.
3. Pass the tightening cap through the cable, insert the cable into the connector, and tighten the hexagonal nut to secure the cable.
• Hook the small protrusion on the Mounting Latch
into the groove on the other side of the lever, then
push up the Switch Block in the direction indicated
by the arrow in the figure below.
Mounting
Latch
(1) Installing the Switch Blocks
(1) Mounting the Switch
http://www.ia.omron.com/
Switch block
Lock nut
Protrusion
Inside
Box
Lever
Snap-in Legend Plate
Outside
• Insert a screwdriver between the Mounting Latch
Rubber washer
and the Switch Block, then push down the
screwdriver in the direction indicated by the arrow
in the following figure.
Use either of the following screwdrivers.
Flat-head screwdriver
Phillips screwdriver
(2) Removing the Switch Blocks
(3) Securing the Connector Cable
Connector
3 to 6 mm dia.
3 to 6 mm
Tightening
Place the tip of a screwdriver on the surface where the cable port hole is to be
created with the cover attached and strike the screwdriver to punch a hole.
Attempts to punch a hole on the other side of the case will damage the Box.
Screwdriver
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Cable
(2) Creating a Cable Port Hole
• Loosen the terminal screw from the Switch
Screw
Unit until it completely comes off the groove,
insert a screwdriver as shown in the following
figure, then push up the washer in the
direction indicated by the arrow to temporarily
secure it. Now, a round crimp terminal can be
connected. After inserting the terminal,
tighten the screws to complete wiring.
Washer
7 to 9 dia.
9 to 11 dia.
Cable diameter
Wiring
A22Z-3500-1
A22Z-3500-2
Connector
Screwdriver
A22E
18

Related parts for A22Z-EG1