A165E-S-03U Omron, A165E-S-03U Datasheet

E-stop,non-lighted,30diameter

A165E-S-03U

Manufacturer Part Number
A165E-S-03U
Description
E-stop,non-lighted,30diameter
Manufacturer
Omron
Datasheets

Specifications of A165E-S-03U

Control Type
Emergency Stop
Contact Form
3PST - NC
Contact Rating
1A at 30 VDC/125 VAC, 0.5 A at 250 VAC
Illuminated
N
Contact Configuration
3PST-NC
Switch Operation
Pushlock Turn Reset
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Current Max
5A
Actuator Style
Round
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
J CONSTRUCTION
For Panel Cutout of 16 mm
H
H
H
H
H
H
Ordering Information
Note: A165E Emergency Stop Switch must be
A165-E
Protective Structure and Terminal Type
Lamp
Safety Features to Prevent Misuse
Push-Lock, Turn-Reset System
Emergency Stop Switch
Modular construction, easy installation
Positive opening mechanism with a
minimum contact separation of 3 mm in
accordance with EN60947-5-1,
contacts
Conforms to EN418, EN60947-5-1
High reliability, IP65
Short mounting depth, less than 28.5 mm
below panel
Quick and easy assembly, snap-in Switch
Unit
Protective Structure
Oil-resistant IP65
Terminal Type
Solder terminals
(tab terminals #110)
LED
Contact open
ordered as a set. No LED is installed for
the non-lighted model.
Contact closed
for NC
2
Safety Lock
Even if an object or person touches the pushbutton by
mistake, the contact will not be released until after the
pushbutton reaches the lock position.
Lock position
Illumination Colors
Switch Unit Specifications
Illumination Method
LED Illumination Red
Non-lighted Red
General-Purpose Loads
125 VAC: 5 A
250 VAC: 3 A
30 VDC: 3 A
LED
R
c
R

Related parts for A165E-S-03U

A165E-S-03U Summary of contents

Page 1

... Oil-resistant IP65 Terminal Type • Solder terminals (tab terminals #110) Lamp LED • Note: A165E Emergency Stop Switch must be ordered as a set. No LED is installed for the non-lighted model. Safety Features to Prevent Misuse Push-Lock, Turn-Reset System Contact open Contact closed for NC → ...

Page 2

... Switch Unit and Lamps. 3 A165-E Part number Contact General-purpose load (125 VAC 250 VAC VDC SPST-NC A165E-LS-24D-01 DPST-NC A165E-LS-24D-02 SPST-NC A165E-S-01 DPST-NC A165E-S-02 TPST-NC A165E-S-03U SPST-NC A165E-LM-24D-01 DPST-NC A165E-LM-24D-02 SPST-NC A165E-M-01 DPST-NC A165E-M-02 TPST-NC A165E-M-03U Part number A16Z-5070 p A16ZJ-3003 l i A16ZA-3003 ...

Page 3

... Note: LED not mounted. Test them with the LED removed. J OPERATING CHARACTERISTICS Features Characteristics Operating force (OF) max. 14.7 N Releasing force (RF) min. 0 Pretravel (PT) 3.5±0.5 mm (3±0 case of A165EjU series) Standards UL508 EN60947-5-1 A165E-U series 1 A (General use) 0.5 A (General use (Resistive) A165Ej-U series ...

Page 4

... Panel cutout dimensions A165E 30 dia. Lighted type 30 mm diameter +0.1 3 dia. 0 Panel cutout dimensions A165EjU 30 dia. One body type 30 mm diameter +0.2 16 dia. 0 Panel cutout dimensions Mounting ring Lock ring Packing (T0.5) Lock +0.2 16 dia. 10.8±0.5 0 22.1± ...

Page 5

... Panel cutout dimensions A165E Lighted models 40 dia diameter +0.2 16 dia. 0 Panel cutout dimensions A165EjU Non-lighted, 40 dia. one-body models 40 mm diameter +0.2 16 dia. 0 Panel cutout dimensions Mounting ring M16×1 Switch Lock ring Lock Packing (T0.5) 2.6 1.4 +0 ...

Page 6

J ACCESSORIES Yellow Plate (Vinyl Chloride) A16Z-5070 45 dia. Lock Ring Rough surface 15.8 ±0.1 dia. Rough surface 0 15 dia. --0.1 J TERMINAL ARRANGEMENT SPST Switches Note: The L+ and L-- terminals are not available with the non-lighted models. ...

Page 7

A165-E Installation J MOUNTING THE PANEL After installing the Switch, snap in the Socket Unit from the back of the panel. 1. Installing the Switch Attach rubber packing or the Yellow Plate onto the Switch from its terminal side. Insert ...

Page 8

... The A165E-jU allows both a general-purpose load (125 V at 5A, 250 and a microload general-purpose load is applied, however, the microload area cannot be used. If the ...