W28-XQAT-15 Tyco Electronics, W28-XQAT-15 Datasheet

no-image

W28-XQAT-15

Manufacturer Part Number
W28-XQAT-15
Description
W28-XQAT-15=W28
Manufacturer
Tyco Electronics
Datasheet
110
Time vs. Current Trip Curve @ +25°C
Features
• Push to reset.
• Approved to many international standards.
• Replaces slow blow glass cartridge fuse.
• Labor-saving snap-in mounting.
• Button extends for visual trip indication.
Electrical Data @ 25°C
Calibration: Will continuously carry 100% of rating.
Dielectric Strength: Over 1,500 volts RMS.
Maximum Operating Voltages: 32VDC; 250VAC, 50/60 Hz.
Interrupt Capacity: 1,000 amps at 250VAC, 50/60 Hz. and 32VDC in
Dimensions are shown for
reference purposes only.
Agency Approvals
W28 series is UL 1077 Recognized as Supplementary Protectors, File
E69543, and CSA Accepted as Supplementary Protectors (Appliance
Component Protectors), File LR15734. W28 breakers have been
issued Certificate of Suitability CS2190N as supplementary
Equipment Protectors by the Energy Authority of New South Wales,
Australia. W28 breakers are also DEMKO (Denmark) and SEV
(Switzerland) approved. VDE approved for use in office equipment
(AC loads only) and provides 8mm isolation. 16 amp and 20 amp
models do not have VDE, DEMKO and SEV approvals at present.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
1000
900
800
700
600
500
400
300
200
100
175
135
0
.1
3-20 amp models – may trip between 101% and 134%, but
must trip at 135% of rating within one hour at +25°C.
0.25-2 amp models – may trip between 101% and 174%, but
must trip at 175% of rating within one hour at +25°C.
(A)
accordance with UL standard 1077 .
1
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Time In Seconds
10
(A) All 3-20 Amp Models
(B)
Overload
1000%
100%
135%
200%
400%
600%
800%
0.17-0.45 Sec.
Issued 3-03 (PDF Rev. 7-06)
Trip in 1 hour
2.2-15.0 Sec.
0.55-1.8 Sec.
0.27-0.7 Sec.
0.12-0.3 Sec.
Trip Times
No Trip
Catalog 1308242
100
(B) All 0.25-2 Amp Models
Overload
100%
175%
200%
400%
600%
Typical Resistance vs. Current Rating @ +25°C
Specifications and availability
subject to change.
Resettable Overload Capacity: Six times rated current for 0.25 through 2
Reset Time: 180 seconds max. for 0.25 through 2 amp models. 5 to 60
Mechanical/Environmental Data
Termination: .250” (6.35mm) quick connects on-axis with circuit breaker
Mounting: Snaps into panel from front. See Recommended Panel Cutouts.
Approximate Weight: 0.35 oz. (10g).
W28
Push to Reset
Fuseholder-Type
Thermal Circuit Breaker
Note: VDE, Demko, Semko not available on 16A and 20A W28 only.
in Amps
Current
Trip in 1 hour
4.5-28.0 Sec.
Rating
1.0-6.5 Sec.
0.4-4.0 Sec.
Trip Times
0.25
0.50
0.75
1.0
2.0
3.0
4.0
5.0
6.0
7 .0
No Trip
seconds for 3 through 20 amp models.
series
body are standard. Right-angle quick connect terminals are
available as a special order option. Consult the factory for
availability of right-angle terminals.
Soldering to terminals is not recommended.
1000
Resistance
in Ohms
Typical
To use this chart: Read up from the ambient
temperature to the curve, and across to find a
correction factor. Multiply the breaker rating by the
correction factor to determine the compensated
rating. Calculate the overloads in terms of the
compensated rating to use the published trip curve.
Do not use these devices outside their specified
operating temperature ranges.
Ambient Compensation Chart
14.0
3.55
2.0
0.89
0.17
0.069
0.043
0.030
0.026
0.017
1.40
1.30
1.20
1.10
1.00
0.90
0.80
0.70
0.60
Ambient Temperature In Degrees Centigrade (°C)
amp models. Ten times rated current for
3 through 20 amp models.
–20 –10 0
in Amps
Current
Rating
12.0
13.0
14.0
15.0
16.0
20.0
10.0
11.0
8.0
9.0
10 20 30 40 50 60
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Resistance
in Ohms
Typical
0.016
0.014
0.011
0.01
0.009
0.009
0.007
0.007
0.007
0.006
P&B

Related parts for W28-XQAT-15

W28-XQAT-15 Summary of contents

Page 1

... Push to Reset Fuseholder-Type Thermal Circuit Breaker Note: VDE, Demko, Semko not available on 16A and 20A W28 only. Resettable Overload Capacity: Six times rated current for 0.25 through 2 Reset Time: 180 seconds max. for 0.25 through 2 amp models Typical Resistance vs. Current Rating @ +25°C ...

Page 2

... Dimensions are in inches over reference purposes only. (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 (PDF Rev. 7-06 Typical Part Number 11 = Black with No Rate Marking 21 = Red with No Rate Marking 16 20 W28-XQ1A-12 W28-XT1A-12 W28-XQ1A-15 W28-XQ1A-20 W28-XT1A-10 .19 .76 MAX. (4.83) (19.31) I .76 MAX. (19.31) O ...