NC2EBD-DC12V PANASONIC EW, NC2EBD-DC12V Datasheet - Page 6

no-image

NC2EBD-DC12V

Manufacturer Part Number
NC2EBD-DC12V
Description
RELAY
Manufacturer
PANASONIC EW
Datasheet
NC
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Unit weight
Characteristics
*2. 100V DC: 740mW
*3. For the AC type, the operate and release time differs depending on the phase of the input and cutoff times.
*4. Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.
*5. 100V DC: –40 C to +40 C
actual load.
Arrangement
Initial contact resistance, max. Max. 50 m (By voltage drop 6 V DC 1A)
Contact material
Nominal switching capacity
(resistive load)
Max. switching power
(resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity
(Reference value)*
Insulation resistance (Initial)
Breakdown
voltage
(Initial)
Temperature rise
Operate time (at 20 C
Release time (at 20 C
Shock
resistance
Vibration
resistance
Mechanical
Electrical (resistive load)
Conditions for operation,
transport and storage*
(Not freezing and condensing
at low temperature)
Max. Operating speed
Item
Between open
contacts
Between
contact sets
Between
contact and coil
Functional
Destructive
Functional
Destructive
1
–40 F to +104 F
4
68
68
F)
F)
2 Form C
Au-clad AgNi type
Standard: 5A 250V AC, 5A 30V DC
Amber: 3A 250V AC, 5A 30V DC
Standard: 1,250VA, 150W
Amber: 750VA, 150W
250 V AC
Standard: 5A
Amber: 3A (AC), 5A (DC)
360mW
(740mW:
100V DC)
100 A 1V DC
Min. 100M
Measurement at same location as
“Initial breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
1,000 Vrms for 1min. (Detection current: 10mA.)
2,000 Vrms for 1min. (Detection current: 10mA.)
Max. 65 C [Max. 85 C (100V AC)] (By resistive method, nominal voltage)
Max. 20ms
Max. 10ms
Min. 98 m/s
Min. 980 m/s
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10 s.)
10 to 55 Hz at double amplitude of 2 mm
Min. 5 10
Standard: Min. 10
Amber: Min. 10
–40 C to +70 C
–40 F to +158 F
(Max.48V DC),
–40 C to +55 C
–40 F to +131 F
(100V DC)
50 cps
16 g
Single side stable
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
.56 oz
7
2
(at 500V DC)
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10 s.)
(Half-wave pulse of sine wave: 6 ms.)
5
(3A 250V AC), Min. 5 10
DC
5
(5A 250V AC), Min. 5 10
800mW
Set time:
Max. 20ms
Reset time:
Max. 20ms
Min. 5 10
–40 C to +55 C
–40 F to +131 F
2 Coil latching
7
0.50VA to 1.05VA
Max. 30ms*
Max. 40ms*
Min. 10
–40 C to +60 C
–40 F to +140
Single side stable
5
(5A 30V DC)
5
(5A 30V DC)
7
AC
3
3
Specifications
F*
5
4 Form C
Max. 50 m (By voltage drop 6 V DC 1A)
Au-clad AgNi type
Standard: 4A 250V AC, 5A 30V DC
Amber: 2A 250V AC, 5A 30V DC
Standard: 1,000VA, 150W
Amber: 500VA, 150W
Standard: 4A
Amber: 2A (AC), 5A (DC)
720mW*
100 A 1VDC
Min. 100M
Measurement at same location as
“Initial breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
1,000 Vrms for 1min. (Detection current: 10mA.)
2,000 Vrms for 1min. (Detection current: 10mA.)
Max. 20ms
Max. 10ms
Min. 5 10
Standard: Min. 10
Amber: Min. 10
–40 C to +55 C
50 cps
18 g
Single side stable
.63 oz
2
7
(at 500V DC)
5
–40 F to +131 F
(2A 250V AC), Min. 5 10
DC
5
(4A 250V AC), Min. 5 10
1,600mW
Set time:
Max. 20ms
Reset time:
Max. 20ms
Min. 5 10
2 Coil latching
7
1.08VA to 1.30VA
Max. 30ms*
Max. 40ms*
Min. 10
–40 C to +40 C
–40 F to +104 F
Single side stable
5
(5A 30V DC)
5
(5A 30V DC)
7
AC
3
3

Related parts for NC2EBD-DC12V