IALK111-4-51-.050-01 AIRPAX, IALK111-4-51-.050-01 Datasheet - Page 12
IALK111-4-51-.050-01
Manufacturer Part Number
IALK111-4-51-.050-01
Description
CIRCUIT BREAKER
Manufacturer
AIRPAX
Datasheet
1.IAL1-1-59-15.0-01.pdf
(25 pages)
139
OPERATING CHARACTERISTICS
Notes: DCR and impedance based on 100% rated current applied and stablized a minimum of one hour.
Tolerance: .02 amperes to 2.5 amperes, ± 20%; 2.6 amperes to 20 amperes, ± 25%; 21 amperes to 50 amperes, ± 50%. Consult factory for special values and for coil
impedance of delays not shown
0.20
1.0
2.0
5.0
10.0
20.0
30.0
50.0
60.0
70.0
80.0
90.0
100.0
125.0**
150.0**
165.0**
175.0**
200.0**
NOmINAL DCR /ImPEDANCE
IAL/IUL/IEL/LEL Series - Operating Characteristics
Current Ratings
(Amps)
51, 52, 53, 59
45.8
1.38
0.371
0.055
0.017
0.006
0.003
0.0019
0.00142
0.00138
0.00133
0.00127
0.00127
0.0005
0.0005
0.0004
0.0004
0.0004
Resistance (ohms)
DC Delays
61, 62, 63, 69
28.5
1.10
0.29
0.51
0.016
0.006
0.004
0.0018
0.00121
0.00118
0.00112
0.00107
0.00107
—
—
—
—
—
AC, 50/60Hz Delays
Impedance (ohms)
41, 42, 43, 49
71.94
2.85
0.76
0.12
0.032
0.010
0.006
0.006
—
—
—
—
—
—
—
—
—
—
http://airpax.sensata.com/
Impedance (ohms)
AC, 400Hz Delays