HJ4-T-AC120V PANASONIC EW, HJ4-T-AC120V Datasheet - Page 4

no-image

HJ4-T-AC120V

Manufacturer Part Number
HJ4-T-AC120V
Description
HJ4 Relay (Plug-in W/ Test Button)
Manufacturer
PANASONIC EW
Datasheet
2. Specifications
Notes: In accordance with the Electrical Appliance and Material Safety Law, you cannot exceed a voltage of 150V AC when using the 4 Form C type.
REFERENCE DATA
1-(1). Max. switching capacity (2 Form C type)
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Unit weight
Characteristics
For more information, please inquire.
When using low level loads, contact instability may result depending on conditions of use (switching frequency and ambient conditions, etc.); therefore, please use
the Au plating type.
*1 This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
*2 For the AC coil types, the operate/release time will differ depending on the phase.
*3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value.
0.5
0.1
10
7
5
1
actual load.
Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.
AC resistive
DC inductive load
L/R=7ms
10
DC resistive load
load
Arrangement
Initial contact resistance, max
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity
(Reference value)*
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Temperature rise (at 70 C
Operate time*
Release time*
Shock resistance
Vibration resistance
Mechanical
Electrical (resistive load) (at 20 cpm)
Conditions for operation, transport and storage*
(Not freezing and condensing at low temperature)
Max. Operating speed
AC inductive load
cos =0.4
AC resistive load
With test button type only
Contact voltage, V
50
100 125 250
2
2
1
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Item
Au plating type
Without Au plating type
Between open contacts
Between contact sets
Between contact and coil
Functional
Destructive
Functional
Destructive
158
F)
1-(2). Max. switching capacity (4 Form C type)
0.5
0.1
5
3
1
3
AC resistive
DC resistive load
10
load
DC inductive load
L/R=7ms
2 Form C
Max. 50 m (By voltage drop 6 V DC 1A)
Au plating type: Au plating Ag Without Au plating type: Ag
7 A 250V AC
1,750 VA
250V AC, 125V DC
7 A
0.9W 1.2 VA
1mA 1V DC
1mA 5V DC
Min. 100M
Measurement at same location as “Initial breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
2,000 Vrms for 1min. (Detection current: 10mA.)
2,000 Vrms for 1min. (Detection current: 10mA.)
Max. 60 C (By resistive method, nominal voltage)
Max. 20ms (Nominal voltage applied to the coil, excluding contact bounce time.)
Max. 20ms (Nominal voltage applied to the coil, excluding contact bounce time.)
(without diode)
Min. 100 m/s
Min. 1,000 m/s
10 to 55 Hz at double amplitude of 1.0 mm (Detection time: 10 s.)
10 to 55 Hz at double amplitude of 1.0 mm
Min. 2 10
Min. 10
Min. 5 10
Ambient temperature: –40 C to +70 C
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm (at rated load)
Approx. 34g
AC inductive load
cos =0.4
Contact voltage, V
5
(7A 250V AC)
50
7
5
(at 180 cpm)
(5A 250V AC)
2
1.20 oz
(at 500V DC)
(Half-wave pulse of sine wave: 11 ms; detection time: 10 s.)
100 125 250
2
(Half-wave pulse of sine wave: 6 ms.)
2-(1). Life curve (2 Form C)
Specifications
–40 F to +158 F
500
100
4 Form C
5 A 250V AC
1,250 VA
5 A
Min. 10
Min. 2 10
Approx. 34g
50
10
0
AC 250V (cos =0.4)
5
1
(5A 250V AC)
5
(3A 250V AC)
1.20 oz
2
3
Load current, A
AC 250V (cos =1)
4
5
6
HJ
7

Related parts for HJ4-T-AC120V