G9SB-3012-A Omron, G9SB-3012-A Datasheet - Page 3

no-image

G9SB-3012-A

Manufacturer Part Number
G9SB-3012-A
Description
3PST-NO SAFETY RELAY UNIT
Manufacturer
Omron
Datasheet

Specifications of G9SB-3012-A

Contact Form
3PST - NO
Coil Voltage
24 VAC/VDC
Contact Rating
5 A
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Connections
Internal Connections
G9SB-2002-A/C (24 VAC/VDC)
G9SB-3012-A/C (24 VAC/VDC)
G9SB-200-B/D (24 VAC/VDC)
G9SB-301-B/D (24 VAC/VDC)
Wiring of Inputs and Outputs
Note: Grounding
*1. Safety Inputs
*2. Output Contacts
Power supply input
Safety input 1 *1
Safety input 2 *1
Feedback/reset input
Instantaneous safety outputs
Auxiliary output
A1 A2
(1) G9SB-3010 directly cuts off power, and has no Safety Input.
(2) For 1-channel input with G9SB-@@@-B/D, short circuit T12-T22 and then input.
(3) With G9SB-@@@2-A/C, 1-channel input wiring is not possible.
G9SB-2002-A/C: Safety Output Contacts 13-14, 23-24.
G9SB-3012-A/C: Safety Output Contacts 13-14, 23-24, 33-34. Auxiliary Contact 41-42.
G9SB-200-B/D: Safety Output Contacts 13-14, 23-24.
G9SB-301-B/D: Safety Output Contacts 13-14, 23-24, 33-34. Auxiliary Contact 41-42.
G9SB-3010: Safety Output Contacts 13-14, 23-24, 33-34. Auxiliary Contact 41-42.
A1 A2 T11
+ -
TH
SA
+ -
TH
SA
Be sure to ground externally, such as at the power supply.
T21
Signal name
T11
T12
K1
T21
K1
T12
K1
K1
a
T22
K2
K2
a
a
T22
K2
K2
K2
T31
Control
circuit
a
K2
T32
T31
Control
circuit
K1
T32
A1, A2
T11, T12
T21, T22
T31, T32
See below. *2
See below. *2
Terminal name
K1
K1
K2
K1
K2
13
14
13
14
23
24
23
24 (34) (42)
* *
(33)
(34) (42)
* *
* *
(33) (41)
* *
(41)
The input terminals for power supply. Connect the power source to the A1 and A2 terminals.
DC inputs have polarity, so A1 should be connected to the positive side and A2 to the negative side.
To set the safety outputs in the ON state, the ON state signals must be input to both safety input 1 and
safety input 2. Otherwise the safety outputs cannot be in the ON state.
To set the safety outputs in the ON state, the ON state signal must be input to T31 - T32. Otherwise the
safety outputs cannot be in the ON state.
Turns ON/OFF according to the state of the safety inputs and feedback/reset inputs.
Synchronized with Instant Safety Output.
G9SB-3010 (24 VDC)
Note: 1. For 1-channel input with G9SB-@@@-B/D models, short
* Only G9SB-301@-@ models have terminals 33-34 and 41-42.
A1
+
TH
SA
2. Always provide a protective ground externally, e.g., on the
A2
-
terminals T12 and T22. It is not possible to wire
G9SB-@@@2-A/C models for 1-channel input.
power supply.
Description of operation
K1
K1
a
K2
K2
a
K2
T31
Control
circuit
T32
K1
K2
K1
13
14
23
24
33
34 42
41
G9SB
3