CUB30000 Red Lion Controls, CUB30000 Datasheet

Counter

CUB30000

Manufacturer Part Number
CUB30000
Description
Counter
Manufacturer
Red Lion Controls
Series
CUB3r
Type
Electronic Counterr
Datasheet

Specifications of CUB30000

Count Rate
100Hz
Number Of Digits/alpha
6
Input Type
Switch Closure or Transistor Switch
Voltage - Supply
3V, 2 "N" Cell Batteries
Display Type
LCD Non-Backlit
Application
Electronic Counters
Brand/series
CUB3
Dimensions
1.10 H × 2.09 W × 1.87 D Inches
Display Digit Height
0.2 Inches
Mounting Type
Panel
Number Of Digits
6
Primary Type
Counter
Signal, Input
Switch Contact or Solid State Transistor
Special Features
Self-Powered, Low-Cost/High Performance
Termination
12 Inch Leadwires
Voltage, Supply
3 Volt Batteries
Available In Two Versions
Front Reset/Remote Reset
Count Speed
100 Counts/Sec
Operating Temp.
–30°C to +75°C
Weight
3 Oz.
Panel Cutout
1" × 2"
Digit Height
5.1mm
Operating Temperature Range
-30°C To +75°C
No. Of Digits / Alpha
6
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
CUB III
CUB-30-00
CUB-30-00/A
CUB-30-000/A
CUB3
RLC03
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL CUB 3 & CUB3R -
DESCRIPTION
reset, while the CUB3R has remote reset. These units fill a wide variety of
applications.
standard rectangular opening without screws or other hardware. Hook-up is
simply a matter of connecting two wires, and since the operating voltage is only
3 V and with currents in microamps, almost any kind of wire can be used. No
external power is required since the internal batteries provide years of
uninterruptible service. In addition to these advantages, the CUB 3’s offer the
inherent ruggedness, reliability, and permanence of completely integrated
circuitry, embedded in a single monolithic, silicon, micro-chip.
SAFETY SUMMARY
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
SPECIFICATIONS
1. DISPLAY: 6-Digit, LCD, 0.2" (5.1 mm) High.
2. POWER: 3 Volts supplied by 2 replaceable Alkaline “N” Cells. Nominal
3. RESET:
4. COUNT INPUT: Switch Contact or Solid-State Transistor Switch (See
5. COUNT SPEED: 100 counts/sec (6000 counts/min). Min. input pulse width
ORDERING INFORMATION
Note: Batteries not supplied with counter, order separately.
APPLICATIONS
The CUB3s are miniature electronic counters. The CUB3 has front panel
The CUB3s feature a rugged reinforced nylon case that snap-fits into a
All safety related regulations, local codes and instructions that appear in the
battery life 4 years. Battery life is dependent upon usage. Count and reset
contacts that remain closed for long periods of time reduce battery life.
CUB 3 - Via front panel reset button only.
CUB 3R - (Remote Reset Only) Switch Contact or Solid State Transistor
Connections). Contact burden 14 µA; Max. OFF-State leakage current must
be less than 2 µA. Counter increments on negative going edge of input.
5 msec, with 5 msec spacing between count pulses.
IDEAL FOR PORTABLE, MOBILE, OR STATIONARY INDUSTRIAL
MODEL NO.
Switch (See Connections). Contact burden 14 µA; Max. OFF-State
leakage current must be less than 2 µA. Counter resets with negative pulse
with a min. pulse width of 5 msec.
CUB3R
CUB3
BNA
DESCRIPTION
CUB3 (Front Panel Reset Only)
CUB3 (Remote Reset Only)
1.5 V Alkaline “N” Cells (2 Req’d)
ECONOMICAL REPLACEMENT FOR ELECTRO-MECHANICAL COUNTERS
GENERAL PURPOSE, MINIATURE ELECTRONIC COUNTERS
PART NUMBERS
CUB3R000
CUB30000
BNA00001
6. ENVIRONMENTAL CONDITIONS:
7. CERTIFICATIONS AND COMPLIANCES:
Note:
Refer to the EMC Installation Guidelines section of this bulletin for additional
8. CONSTRUCTION: Installation Category I, Pollution Degree 2
9. WEIGHT: 3 oz. (85 g) [Less Batteries]
FRONT PANEL RESET OR REMOTE RESET
COLLECTOR INPUTS
MECHANICAL WEAR
POWER WIRING
PANEL OPENING
Operating Temperature: -30° to +75°C
Storage Temperature: -40° to +80°C
Vibration According to IEC 68-2-6: Operational 5 to 500 Hz, in X, Y, Z
Shock According to IEC 68-2-27: Operational 30 g, 11 msec in 3 directions.
Operating and Storage Humidity: 85% max. relative humidity (non-
Altitude: Up to 2000 meters
SAFETY
ELECTROMAGNETIC COMPATIBILITY
Immunity to EN 50082-2
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
RF conducted interference
Power frequency magnetic fields EN 61000-4-8
Simulation of cordless telephones
Emissions to EN 50081-2
RF interference
information.
AVAILABLE IN TWO VERSIONS:
LOW COST/HIGH PERFORMANCE
OPERATES FROM SWITCH CONTACT OR NPN OPEN
PROVIDES YEARS OF SILENT OPERATION WITHOUT
SELF POWERED, 2-WIRE CONNECTION, ELIMINATES
EASY SNAP-IN MOUNTING IN 1" X 2" (25 mm x 50 mm)
direction for 1.5 hours, 5g’s.
condensing) from 0°C to 50°C.
IEC 1010-1, EN 61010-1: Safety requirements for electrical equipment for
measurement, control, and laboratory use, Part 1.
CAUTION: Read complete instructions prior to
installation and operation of the unit.
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-6
ENV 50204
EN 55011
Level 2; 4 Kv contact
Level 3; 8 Kv air
Level 3; 10 V/m
80 MHz - 1 GHz
Level 4; 2 Kv I/O
Level 3; 2 Kv power
Level 3; 10 V/rms
150 KHz - 80 MHz
Level 4; 30 A/m
Level 3; 10 V/m
900 MHz, ±5 MHz
200 Hz, 50% duty cycle
Enclosure class A
Power mains class A
Bulletin No. CUB3/R-F
Drawing No. LP0126
Released 02/09

Related parts for CUB30000

CUB30000 Summary of contents

Page 1

... Emissions to EN 50081-2 RF interference Note: Refer to the EMC Installation Guidelines section of this bulletin for additional information. 8. CONSTRUCTION: Installation Category I, Pollution Degree 2 9. WEIGHT: 3 oz. (85 g) [Less Batteries] PART NUMBERS CUB30000 CUB3R000 BNA00001 Bulletin No. CUB3/R-F Drawing No. LP0126 Released 02/09 EN 61000-4-2 Level contact Level 3 ...

Page 2

... INTERNAL CLASP. RIGHT HAND SIDE OF COVER WILL NOW SWING OUT. Fair-Rite # 0443167251 (RLC #FCOR0000) TDK # ZCAT3035-1330A Steward #28B2029-0A0 India Building 13, No.99 Tianzhou Road Red Lion Controls China Unit 101, XinAn Plaza ShangHai, P.R. China 200223 Tel +86 21 6113-3688 Fax +86 21 6113-3683 ...

Related keywords