3-1393813-6 Tyco Electronics, 3-1393813-6 Datasheet - Page 12

V23054E 20B133

3-1393813-6

Manufacturer Part Number
3-1393813-6
Description
V23054E 20B133
Manufacturer
Tyco Electronics
Series
V23054/Cradle Relay Sr
Datasheet

Specifications of 3-1393813-6

Rohs Compliant
YES
Contact Form
6 Form C (6PDT), 6 C/O
Coil Voltage
24 VDC
Power Consumption
1000 mW
Contact Carry Current
2 A
Termination Style
Solder Terminal
The maximum voltage stated in the table (page 6) can be increased for impulse operation as follows:
U
U
q
The impulse voltage must not exceed 80% of the test voltage (winding/frame or winding/winding) or not to exceed the
max. voltage as listed in the table (page 6) by no more than 2.3 told.
Ift
Ift
t
If t
Examples of various periodic pulse trains (energizing side)
1. Periodic recurrence of one energizing pulse
2. Periodic recurrence of two unequal energizing pulses
t
t
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Instructions for Impulse Operation
2
ED
I
II Impuls
II tamb
+ t
ED
ED
ED
II
=
=
=
=
=
>
=
=
3 s then q
U
Maximum continuous voltage at ambient temperature t
Factor
Pulse width
Cycle time
3 s the value of q must be obtained from the nomograph (next page).
t
Pulse widths within one cycle
I
II tamb
+ t
II
. q
=
AXICOM
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
amb
108-98014 Rev. C
12 of 18

Related parts for 3-1393813-6