H3DK-FA DC12 Omron, H3DK-FA DC12 Datasheet - Page 13

no-image

H3DK-FA DC12

Manufacturer Part Number
H3DK-FA DC12
Description
TIMER, TWIN ON/OFF DELAY, SPDT, 12VDC
Manufacturer
Omron
Datasheet

Specifications of H3DK-FA DC12

Contact Configuration
SPDT
Delay Time Range
0.1s To 1200h
Adjustment Type
Screwdriver Slot
Relay Mounting
DIN Rail
Svhc
No SVHC (15-Dec-2010)
Contact Current Ac Max
5A
Contact Current Dc
RoHS Compliant
Connections
■ Block Diagrams
H3DK-F
Nomenclature
H3DK-F
ON time range switch
ON output
indicator (orange)
OFF output
indicator (green)
OFF time range switch
ON/OFF start switch
(Default setting is for
an OFF start.)
AC (DC)
input
Power supply
circuit
indicator
ON
Indicator
circuit
Front View
indicator
OFF
ON/OFF time setting
detection circuit
ROM
ON time setting dial
(Sets the ON time.)
OFF time setting dial
(Sets the OFF time.)
User label
attachment location
One-chip microcomputer
RAM
ON/OFF start switch
Clock
Terminal Block
(See notes 1 and 2.)
Output circuit
Time
specification
switches
Bottom View
■ Terminal Arrangement
H3DK-F
Note: The power supply terminals do not have po-
Note 1. Use solid wire (2.5 mm
Note 2. Screw Tightening Torque
18
A1
18
(DIN notation)
R1
15
larity.
A1
A2
16
Using Solid Wire
(2.5 mm
15
16
rules with insulative sleeves to connect
to the terminals.
To maintain the withstand voltage after
connecting the terminals, insert no
more than 8 mm of exposed conductor
into the terminal.
Recommended Ferrules
Phoenix Contact
• AI@@@ Series
• AI-TWIN@@@ Series
Recommended torque: 0.49 N·m
Maximum torque: 0.98 N·m
16
A2
15
2
18
Max.)
8 mm max.
Using Ferrule with
Insulative Sleeve
H3DK-F
2
max.) or fer-
8 mm max.
13