G6K-2F-Y-TR DC9 Omron, G6K-2F-Y-TR DC9 Datasheet - Page 3

SMT TAPE-N-REEL RELAY

G6K-2F-Y-TR DC9

Manufacturer Part Number
G6K-2F-Y-TR DC9
Description
SMT TAPE-N-REEL RELAY
Manufacturer
Omron
Series
G6Kr
Datasheet

Specifications of G6K-2F-Y-TR DC9

Relay Type
Telecom
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
1A @ 30VDC
Coil Type
Standard
Coil Current
11.3mA
Coil Voltage
9VDC
Control On Voltage (max)
7.2 VDC
Control Off Voltage (min)
0.9 VDC
Mounting Type
Surface Mount
Termination Style
Gull Wing
Contact Form
2 Form C
Power Consumption
100 mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G6K-2F-Y-TR-DC9
G6K2FYTRDC9
■ Characteristic data
Shock Malfunction
Maximum Switching Capacity
Shock direction
Electrical Service Life
Conditions:
DC resistive load
125 VAC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
Rated operating voltage (V)
Rated operating current (A)
Shock is applied in ±X, ±Y, and ±Z di
rections three times each with and with
out energizing the Relays to check the
number of contact malfunctions.
30 VDC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
AC resistive load
Not
energized
Unit: m/s
Sample: G6K-2G
Number of Relays: 10
Energized
2
Note: The maximum coil voltage refers to the maxi-
Electrical Service Life
(with Must Operate and Must
Release Voltage) (See note.)
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs.
Maximum Coil Voltage
Ambient Temperature vs. Must
Operate or Must Release Voltage
G6K-2G (F/P), G6K-2G (F/P)-Y
mum value in a varying range of operating
power voltage, not a continuous voltage.
Operating frequency (x10 operations)
Note: The tests were conducted at an
Must operate
Sample: G6K-2G
Number of Relays: 10
Test conditions: 1 A resistive load at
30 VDC with an operation rate of 50%
Switching frequency: 1,800 operations/h
Must release
ambient temperature of 23°C.
Ambient temperature (°C)
Ambient temperature (°C)
Max. estimated value
3
Operate voltage
Release voltage
Electrical Service Life
(Contact Resistance) (See note.)
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs.
Switching Current
Ambient Temperature vs. Must
Set or Must Reset Voltage
G6KU-2G (F/P)-Y
Low Signal Relay
Operating frequency (x10
Note: The tests were conducted at an
Switching frequency: 1,800 operations/h
Sample: G6K-2G
Number of Relays: 10
Test conditions: 1 A resistive load
at 30 VDC with an operation rate of 50%
Contact resistance
ambient temperature of 23°C.
Ambient temperature (°C)
Ambient temperature (°C)
Max. estimated value
G6K
3
operations)
NO
contact
NC
contact
69

Related parts for G6K-2F-Y-TR DC9