G4Q-212S DC24 Omron, G4Q-212S DC24 Datasheet - Page 4

no-image

G4Q-212S DC24

Manufacturer Part Number
G4Q-212S DC24
Description
Relay
Manufacturer
Omron
Series
G4Qr
Datasheet

Specifications of G4Q-212S DC24

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
5A
Switching Voltage
250VAC, 250VDC - Max
Coil Type
Standard
Coil Current
162mA
Coil Voltage
24VDC
Turn On Voltage (max)
16.8 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
5A @ 220VAC
Control On Voltage (max)
16.8 VDC
Control Off Voltage (min)
2.4 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G4Q-212SDC24
G4Q212SDC24
Operation
Note: When a pulse for application to the coil is used, such a pulse
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Operation Timing Chart
Ambient Temperature vs.
Coil Temperature Rise
100 VAC 50 Hz
Open Model
G4Q-211A
Contact terminal
(NO) (1−3, 8−6)
Contact terminal
(NC) (1−4, 8−5)
Coil terminal
100 ms min.
should have a width of 100 ms or more. If a pulse is applied with
a width less than the operate time, the cam may fail to rotate
fully.
Contact with no carry current
Contact carry current: 5 A
Ambient temperature (°C)
66.5 max. 58
Four, 3.5-dia.
mounting holes
56 max.
25
24 VDC
Contact with no carry current
Contact carry current: 5 A
65 max.
Ambient temperature (°C)
Terminal Arrangement/
Internal Connections
Malfunctioning Shock
Shock direction
Mounting Holes
25±0.2
Energized
Number of samples: 5
Measurement conditions:
Impose a shock of
100 m/s
±Z directions three times
each with the Relay
energized and not
energized to check the
shock values that cause
the Relay to malfunction.
Four, M3 mounting
screw holes or four
3.5-dia. holes
Not
energized
58±0.2
2
Unit: m/s
in the ±X, ±Y, and
2
G4Q
4

Related parts for G4Q-212S DC24