G3TC-IAC5A AC/DC 240 Omron, G3TC-IAC5A AC/DC 240 Datasheet - Page 11

Solid State Relay

G3TC-IAC5A AC/DC 240

Manufacturer Part Number
G3TC-IAC5A AC/DC 240
Description
Solid State Relay
Manufacturer
Omron
Series
G3TCr
Type
ACr
Datasheet

Specifications of G3TC-IAC5A AC/DC 240

Color
Yellow
Style
Standard
Voltage - Input
180 ~ 280VAC (240VAC Nom)
Current - Input
5mA
Logic Supply Voltage (output)
5VDC (4.5 ~ 6VDC)
Logic Supply Current (output)
18mA
Turn On Time
20ms
Turn Off Time
20ms
Features
Hold Down Screw
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
G3TC-1AC-5A
G3TC-1AC-5A AC/DC240
G3TC-1AC-5AAC/DC240
G3TC-IAC-5A
G3TC-IAC-5A AC/DC240
G3TC-IAC-5AAC/DC240
G3TCIAC5A AC/DC240
G3TCIAC5AACDC240
Z2018
■ Operating and Storage Environments
Operating Ambient Temperature
The rated value for the ambient operating temperature of the G3TC
is for when there is no built-up heat. For this, reason, under condi-
tions where heat dissipation is not good due to poor ventilation, and
where heat may build up easily, the actual temperature of the G3TC
may exceed the rated value resulting in malfunction or burning.
When using the G3TC, design the system to allow heat dissipation
sufficient to stay below the Load Current vs. Ambient Temperature
characteristic curve. Note also that the ambient temperature of the
G3TC may increase as a result of environmental conditions (e.g., cli-
mate, air-conditioning) and operating conditions (e.g., mounting in an
airtight panel).
Operating and Storage Locations
Do not use or store the G3TC in the following locations. Doing so
may result in damage, malfunction, or deterioration of performance
characteristics.
1. Do not use or store in locations subject to direct sunlight.
2. Do not use in locations subject to ambient temperatures outside
3. Do not use in locations subject to relative humidity outside the
4. Do not store in locations subject to ambient temperatures outside
5. Do not use or store in locations subject to corrosive or flammable
6. Do not use or store in locations subject to dust (especially iron
7. Do not use or store in locations subject to shock or vibration.
8. Do not use or store in locations subject to exposure to water, oil,
Transportation
When transporting the G3TC, observe the following points. Not doing
so may result in damage, malfunction, or deterioration of perfor-
mance characteristics.
1. Do not drop the G3TC or subject it to severe vibrations or shock.
2. Do not transport the product if it is wet.
Vibration and Shock
Do not subject the SSR to excessive vibration or shock. Otherwise
the SSR may malfunction and internal components may be dam-
aged.
the range -30° to 80°C.
range 45% to 85% or locations subject to condensation as the
result of severe change in temperature.
the range -30° to 100°C.
gases.
dust) or salts.
or chemicals.
Solid State Relays for Industrial I/O
G3TC
405

Related parts for G3TC-IAC5A AC/DC 240