G2R-2-T130 DC18 Omron, G2R-2-T130 DC18 Datasheet - Page 6

no-image

G2R-2-T130 DC18

Manufacturer Part Number
G2R-2-T130 DC18
Description
RELAY
Manufacturer
Omron
Series
G2Rr
Datasheet

Specifications of G2R-2-T130 DC18

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
5A
Switching Voltage
380VAC, 125VDC - Max
Coil Type
Standard
Coil Current
29.4mA
Coil Voltage
18VDC
Turn On Voltage (max)
12.6 VDC
Turn Off Voltage (min)
2.7 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
5A @ 250VAC
Control On Voltage (max)
12.6 VDC
Control Off Voltage (min)
2.7 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G2R-2-T130DC18
G2R2T130DC18
G2R
Double-winding Latching Relays
Note:
I
UL 508 (File No. E41643)
6
Contact resistance
Set time
Reset time
Min. set/reset signal width
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
G2R-1
G2R-14
G2R-1-H
G2R-1-S
G2R-1-T
G2R-1A
G2R-1A4
G2R-1A-H
G2R-1A-S
G2R-1A-T
G2R-1-E
G2R-1A-E
G2R-2
G2R-24
G2R-2-H
G2R-2-S
G2R-2A
G2R-2A4
G2R-2A-H
G2R-2A-S
G2R-1A-ASI
Approved Standards
Values in the above table are the initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.
Model
Item
SPDT
SPST-NO
SPDT
SPST-NO
DPDT
DPST-NO
SPST-NO
30 m
20 ms max.
20 ms max.
30 ms max.
Mechanical:18,000 operations/hr
Electrical:
1,000 M
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same pole;
1,000 VAC, 50/60 Hz for 1 min between set and
reset coil
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: Set: 500 m/s
Reset:
Mechanical: 10,000,000 operations min (at 18,000 operations/hr)
Electrical:
Operating: 40°C to 70°C (with no icing)
Operating: 5% to 85%
Approx. 17 g
Contact form
max.
min. (at 500 VDC)
1,800 operations/hr (under rated load)
100,000 operations min. (at 1,800 operations/hr under rated load)
100 m/s
2
1 pole
(approx. 10G)
2
3 to 110 VDC
3 to 240 VAC
(approx. 100G)
2
Coil ratings
(approx. 50G); 200m/s
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
16 A, 30 VDC (resistive, NO contact only)
16 A, 250 VAC (general use, NO contact only)
TV-3 (NO contact only); 1/3 hp, 120 VAC
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
10 A, 250 VAC (general use)
TV-5/TV-8 (NO contact only)
10 A, 30 VDC (resistive)
2
50 m
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts
of different poles
1,000 VAC, 50/60 Hz for 1 min between contacts
of same pole
1,000 VAC, 50/60 Hz for 1 min between set and
reset coil
(approx. 20G)
max.
Contact ratings
2 poles
G2R

Related parts for G2R-2-T130 DC18