D4CC-1024 Omron, D4CC-1024 Datasheet
D4CC-1024
Specifications of D4CC-1024
Related parts for D4CC-1024
D4CC-1024 Summary of contents
Page 1
... VCTF oil-resistant cables with CE marking. (Applicable only to standard models.) Model Number Structure Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) Standard Models D4C-@@@ (1)(2)(3) (1) Rated Current 250 VAC VDC ...
Page 2
... Note: 1. Models are available separately with resistance to viscous oils (oil drain holes are provided), but only with Plunger Models. Add “-M” to the model number (example: D4C-1202 would be D4C-1202-M). Ask your nearest OMRON representative for details. 2. Switches with variable roller levers are also available. Ask your nearest OMRON representative for details. *1. Oil-resistant vinyl cabtire cables; approved by EN and IEC. ...
Page 3
... D4C-2350 3 D4C-2260 Center roller lever 5 D4C-2360 Note: Ask your nearest OMRON representative for information on Switching with approved international standards. *1. Oil-resistant vinyl cabtire cables; approved by EN and IEC. *2. Ordinary vinyl cabtire cables.; approved by EN and IEC. 0 125 VAC VCTF cable *2 Model D4C-2401 ...
Page 4
... Roller lever (high- sensitivity model) Note: 1. The @ contains the length of the cable. For example → D4C-2002-AK1EJ03 2. M1J models are also available. Contact your OMRON sales representative for further information the above model numbers, some with special specifications are not registered. Weather-resistant Models Operation ...
Page 5
Applicable Cables No. of Appearance conductors Straight 4 Mounting Plates (Order Separately) The WL model incorporated by equipment can be replaced with the D4C together with the Mounting Plate without changing the position of the dog or cam. List of ...
Page 6
... Weight (D4C-1202) Note: The above figures are initial values. *1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. Pre-wired Models: 1,000,000 operations min. (DC specifications, switching current: 0 ...
Page 7
Engineering Data Electrical Durability @@@ @@@ @@@ D4C 500 Operating temperature: 20 ± 2 ° C Operating humidity: 65 ± 5 ° C Operating frequency: 30 operations/min 300 (cosΦ 100 125 VAC ...
Page 8
Contact Form Standard Models/Weather-resistant Models Without Operation Indicator (black)COM NC (red With Operation Indicator (Lit when Not Actuated) <24 VDC LED> (black) COM NC (red Ω <100 VAC LED> (black) COM NC (red) NO ...
Page 9
... Dimensions and Operating Characteristics Switches Models without LED indicators are shown in the illustrations and dimensions diagrams. Refer to page 11 for Models with LED Indicators. Standard Models The boxes in the model numbers are replaced with the rating and cable type. Refer to page 1 for the Model Number Structure. ...
Page 10
Sealed Plunger D4C-@@31 10 dia. stainless steel plunger 40 max ± 0 max. VCTF cable conductor Finishing O.D.: 7.6 34 Sealed Crossroller Plunger D4C-@@33 12 dia. x 4.4 stainless steel roller ...
Page 11
... N Pretravel PT max. 1.8 mm Overtravel OT min Movement Differential MD max. 0.2 mm Operating Position OP 15.7±1 mm Note: Specifications are the same for -M1J Switches. Center Roller Lever Plunger D4C-@@ 3.2 dia. 6.6 dia. Rubber cap +0.2 Two, 5.1 dia. 0 holes Spot facing 10.2 dia. Depth ...
Page 12
... Operating characteristics 6 dia. Operating force OF Release force Pretravel Overtravel Movement Differential MD Operating Position Note: Specifications are the same for -M1J Switches D4C 12 dia. x 4.4 stainless steel roller 40 max. Rubber cap 25 ± 0.1 16 +0.2 Two, 5.1 dia. 0 holes Spot facing 10 ...
Page 13
... Always appraise performance under actual application conditions and set suitable maintenance and replacement periods. • Install Switches where they will not be directly subject to cutting chips, dust, or dirt. The Actuator and Switch must also be protected from the accumulation of cutting chips or sludge. ...
Page 14
... Please check the load's OFF current before use the indicator- equipped switch. Mounting • A maximum of 6 Switches may be group-mounted. In this case, pay attention to the mounting direction so that the convex part of the group-mounting guide on one Switch fits into the concave part of the guide on the other Switch as shown in the figure below. For group mounting, the mounting panel must have a thickness ( min ...
Page 15
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...