Page 1
... General-purpose Maintained-contact models General-purpose Basic Models General-purpose • A variety of actuators is available for a wide range of application. • The contact mechanism of models for micro loads is a crossbar type with gold-alloy contacts, which ensures highly reliable operations for micro loads. • Contact Gap: H2: ...
Page 2
... Panel mount plunger (high-sensitivity, (medium OP) micro load) Q8: Panel mount plunger (high OP) G: 0.5 mm Q22: Panel mount roller plunger E: 1.8 mm (high-capacity) Q21: Panel mount cross roller plunger L: Leaf spring (high OF) L2: Roller leaf spring W21: Short hinge lever W: Hinge lever (low OF) ...
Page 3
... Ordering Information Basic Models (General-purpose) Classification Actuator Contact gap Terminal *1 Pin plunger Slim spring plunger Short spring plunger Low OP Panel mount plunger Medium OP High OP Panel mount roller plunger Panel mount cross roller plunger Leaf spring Roller leaf spring Short hinge lever ...
Page 4
... Classification Actuator Contact gap Terminal *1 Hinge cross roller lever Unidirectional short hinge roller Parallel Z-15GW2277-B lever Reverse hinge lever *2 Reverse short hinge roller lever *2 Reverse hinge roller lever *2 *1. : Solder terminal : Screw terminal *2. The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating the levers ...
Page 5
... Drip-proof Models Classification Contact gap Drip-proof terminal protective cover Actuator Terminal *1 Pin plunger Short spring plunger Low OP Spring plunger High OP Panel mount plunger Panel mount roller plunger Panel mount cross roller plunger Leaf spring Roller leaf spring Short hinge lever Long hinge lever ...
Page 6
... Ambient purpose operating humidity 35% to 95%RH Drip-proof Contact gap H2: 10,000,000 operations min. Mechanical Contact gap G, H: 20,000,000 operations min.(*4) Contact gap E: 300,000 operations Service life Contact gap G, H: 500,000 operations min. Electrical Contact gap E: 100,000 operations min. Approx Weight *1 The values are for the plunger models. (For the lever models, the values are at the plunger section ...
Page 7
... VDC 250 VAC 125 VAC 30 VDC 6. The AC ratings of molded terminals are 125 and 250 V only. 7. The ratings values apply under the following test conditions: (1) Ambient temperature: 20±2°C (2) Ambient humidity: 65±5%RH (3) Operating frequency: 20 operations/min 8. Consult Omron regarding CCC standards and ratings. ...
Page 8
Engineering Data ■ Mechanical Durability 10,000 Ambient temperature: 20±2°C Ambient humidity: 65±5%RH 5,000 Without load Operating frequency: 240 operations/min 3,000 1,000 500 300 100 0 0.1 0.2 0.3 0.4 0.5 ■ Structure Basic Models Contact Form (SPDT) COM NC NO ...
Page 9
... Dimensions ■ General-purpose and Split Contact Models Note: Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions Terminals General-purpose Models Screw Terminals (-B) 9 ± 0.2 17.45 COM NO NC Three, M4 × 5.5 Terminal screws (with toothed washer) 49 ...
Page 10
... Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Pin Plunger Z-15G-B ...
Page 11
... Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Panel Mount Plunger ...
Page 12
... Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Leaf Spring Z-15GL-B ...
Page 13
... Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Low-force Hinge Lever ...
Page 14
... Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Short Hinge Cross Roller Lever Z-15GW49-B Z-15GW54-B (Lever Length: 48 ...
Page 15
... Terminal Protective Cover) Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Terminals 9 ...
Page 16
... Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Panel Mount Plunger ...
Page 17
... Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions +0.075 4.2 Short Hinge Lever Z-15GW2155-B 20 ...
Page 18
... Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Hinge Roller Lever Z-15GW255-B 20 ...
Page 19
... Note: 1. All drawings show the switches with screw terminals. For versions with solder terminals, remove the “-B” from the end of the part number. 2. Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Flexible Rod (Coil Spring) ...
Page 20
... Drip-proof Models (with Terminal Protective Cover) Note: Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Pin Plunger PT Z-15GA55-B5V OP 19.2 Z-15GK3A55-B5V PT OP 19.2 Panel Mount Plunger PT Z-15GQA55-B5V OP 16.3 19.2 PT Panel Mount Roller Plunger Z-15GQ22A55-B5V OP 16.3 19 ...
Page 21
... Note: Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Long Hinge Lever Z-15GW44A55-B5V 20.2 16.9 19.2 Hinge Lever Z-15GWA55-B5V 20.2 16.9 19.2 Short Hinge Roller Lever Z-15GW22A55-B5V 20.2 16.9 19.2 Hinge Roller Lever Z-15GW2A55-B5V 20.2 16.9 19 ...
Page 22
... Note models with molded terminals are approved by UL, CSA, or EN. 2. Molded terminals are not available on all models. Contact your OMRON representative for applicable products. ■ Maintained Contact Models Note: Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions. Pin Plunger PT ...
Page 23
... Safety Precautions Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide, “Snap Action Switches, Technical Information” for correct use. Precautions for Safe Use Terminal Connection When soldering lead wires to the Switch, make sure that the capacity of the soldering iron maximum ...
Page 24
... Switch is connected to such a load. (In this case, the exciting current of the relay coil is the load of the Switch.) • Do not apply a force of 19 higher to the pin plunger. • Exercise care that the environment conditions such as temperature and humidity do not change abruptly. ...
Page 25
... OMRON representative for details. Split-contact Switch (Z-10F@Y) The applicable current varies depending on how the contacts are used. If the Switch is connected in series, the Switch can endure a current 1 times higher than the current that can be applied in parallel connection. Accessories (Order Separately) Refer to “Z/A/X/DZ Common Accessories” datasheet for details about Terminal Covers, Separators, and Actuators. ...
Page 26
... All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B ...