85100636 Crouzet USA, 85100636 Datasheet - Page 161
85100636
Manufacturer Part Number
85100636
Description
SAFETY RLY, KZH3-RS 24VAC-VDC
Manufacturer
Crouzet USA
Series
KZH3-RSr
Datasheet
1.84873004.pdf
(328 pages)
Specifications of 85100636
Contact Form
3PST (3 Form A)
Contact Rating (current)
6A
Switching Voltage
440VAC - Max
Relay Type
Safety
Coil Voltage
24VAC/DC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Coil Type
-
Coil Current
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
- Current page: 161 of 328
- Download datasheet (9Mb)
Operating principles
Contactor
The contactor output is closed when the control voltage is present at the control input terminals.
The contactor output is open when there is no voltage at the control input terminals.
The LED is lit when the output is active.
Impulse relay
The impulse relay output changes state on each impulse at the control input terminals, and remains in that state between each impulse. The output
changes state on the rising edge of the control state change.
The pushbutton on the front can be used to select an operating mode : Automatic (LED lit) : Impulse relay function (Auto)
Forced operation (LED flashing) : output closed (ON)
Stop (LED not lit) : output open (OFF)
Day/night contactor
The contactor output is closed when the control voltage is present at the control input terminals. The contactor output is open when there is no voltage at
the control input terminals.
The pushbutton on the front can be used to select an operating mode : Automatic (LED lit) : Day/night contactor function (Auto)
Forced operation (LED flashing) : output closed (ON)
When the control changes state, the day/night contactor reverts to automatic mode.
Stop (LED not lit) : output open (OFF)
Conformity with standars
IEC/EN 60947-4-3 (industrial environment)
IEC/EN 60669-2-1 (domestic environment)
IEC/EN 60601-1 (medical environment)
IEC/EN 60947-7-1 (connection for industrial env.)
IEC/EN 60998-2-1 (connection for domestic env.)
Insulation coordination:
Breakdown voltage according to IEC/EN60669-2-1:
Insulation resistance according to IEC/EN60669-2-1:
Vibrations according to IEC/EN60068-2-6: frequencies: 10 to 55Hz
For more information www.crouzet.com
Connections
Principles
1
2
1 3
2 4
I N
3
4
A1
A2
90...
260V
A1
A2
Installation category: 3
Degree of pollution: 3
According to IEC/EN60669-2-1:
2 KV/1Min / 1mA / 50 Hz
> 5MΩ /500VDC / 1Min
LOAD
N I
1 3
2 4
A2
A1
90...260 V AC/4...32 V DC
amplitude: 0.35 mm
161
5
Related parts for 85100636
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
SCREW SOCKET (OT08PC)
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
PANEL PLATE FOR 813
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
Controller; CTD46 Dual Display Temperature, 1/16 DIN, NEMA 4X, 110/220VAC
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1084
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1086
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1087
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1089
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1078
Manufacturer:
Crouzet USA
Datasheet:
Part Number:
Description:
11R1079
Manufacturer:
Crouzet USA
Datasheet: