Specifications of MJN2C-N-DC12

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
10A
Switching Voltage
600VAC, 28VDC - Max
Coil Type
Non Latching
Coil Current
100mA
Coil Voltage
12VDC
Turn On Voltage (max)
9 VDC
Turn Off Voltage (min)
-
Features
LED Indicator
Mounting Type
Socketable
Termination Style
Plug In, QC - .187" (4.7mm)
Contact Material
Silver Alloy
Operate Time
20ms
Release Time
10ms
Coil Power
1.2 W
Coil Resistance
120 Ohms
Operating Temperature
-45°C ~ 70°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Latching - DC
Note: 120% of nominal or greater (one second duration single pulse) unlatch voltage - - above this the relay latches again.
■ Characteristics
Note: A latch pulse of 50 ms minimum at nominal voltage is recommended to insure positive latching.
Nominal
voltage
5 VDC
6 VDC
12 VDC
24 VDC
48 VDC
110 VDC
Operate time
Release time
Latch time
Unlatch time
Operating
ambient
temperature
Insulation material
Duty cycle
Shock
Vibration
Life expectancy
Dielectric strength
Terminals
Weight
Maximum continuous voltage: 120% of nominal (one coil only).
Latch coil
resistance in
Ohms ± 10%
14
20
80
330
1,290
5,125
AC: 1 & 2 pole
AC: 3 pole
DC: 1, 2 & 3
pole
Unlatch coil
resistance in
Ohms ± 10%
45
64
275
1,070
2,850
10,750
Operating
Storage
Operating
Storage
Operating
Storage
Electrical at
rated load
Mechanical
Nominal coil power
1.2 W
15 ms nominal; 20 ms maximum
6 ms nominal; 10 ms maximum
13 ms nominal with a one second pulse of nominal voltage (See note)
13 ms nominal with a one second pulse of nominal unlatch voltage after latching with
a one second pulse of nominal latching voltage (See note)
-45° to 60°C (-49° to 140°F)
-65° to 100°C (-85° to 212°F)
-45° to 45°C (-49° to 113°F)
-65° to 100°C (-85° to 212°F)
-45° to 70°C (-49° to 158°F)
-65° to 100°C (-85° to 212°F)
High quality phenolic
15 g’s 11±1 ms (non-operating test, no mechanical damage)
0.1” DA or 10 g’s, 10 to 55 Hz (operating test, no contact chatter)
100,000 operations
10,000,000 operations
Greater than 750 VAC, RMS 60 Hz across open contacts
Greater than 2,500 VAC, RMS 60 Hz all other mutually insulated elements
Quick Connect
64 g (2.3 oz) open relay
54 g (3.0 oz) enclosed relay
Rated for continuous duty operation at 25% overvoltage
Coil
5 to 110 VDC 1,000 MΩ
voltages
General Purpose Relay
Insulation
resistance
min. @ 500
VDC
Operate voltage
(latch/unlatch) at 25°C (77°F)
(see note)
75% of nominal
MJN
319

Related parts for MJN2C-N-DC12