81506710 Crouzet USA, 81506710 Datasheet - Page 7

ADJUSTABLE PNEUMATIC TIMER

81506710

Manufacturer Part Number
81506710
Description
ADJUSTABLE PNEUMATIC TIMER
Manufacturer
Crouzet USA
Datasheets

Specifications of 81506710

Delay Time Range
0.15s To 15s
Timing Adjustment
Knob
Relay Mounting
Panel
Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Rohs Compliant
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
www.crouzet.com
81 541 001
Plug-in
Ø 4
Ø 4 mm
Green
2 • 8
2.7
150
-5 +50
>
13
81 501 025 - 81 503 025
81 504 025 - 81 506 025
ATEX version products are available in the following catologues: Pneumatic products for explosive atmospheres or on our website
www.crouzet.com
10
7
-
-
-
-
-
-
YES element
The output signal "S" is only present when the
pilot is present "a" is present:
S = a YES b
81 541 005
Plug-in
Ø 6
Ø 6 mm
Green
2 • 8
4
200
-5 +50
>
25
10
7
-
-
-
-
-
l
81 501 025
On sub-base
page 36-37
Yellow
2 • 8
2.7
170
< 4
-5 +50
>
30
10
P.p (bars)
7
-
-
-
-
-
l
S = a
P.a (bars)
81 503 025
Threshold
On sub-base page
4/14-4/15
Orange
2 • 8
2.7
170
< 4
-5 +50
>
30
10
P.p (bars)
7
-
-
-
-
-
l
P.a (bars)
81 504 025
Threshold
On sub-base page
4/14-4/15
Light grey
2 • 8
2.7
170
< 4
-5 +50
>
30
10
P.p (bars)
7
-
-
-
-
-
l
NOT element
The output signal "s" is present only if the input signal
"a" is NOT present. The output signal is therefore the
inverse of the pilot signal:
S= NOT a
If the supply port is connected to a 2nd input "b", the
function obtained is called inhibition:
S = NOT a AND b
P.a (bars)
81 506 025
Threshold
On sub-base page
4/14-4/15
Dark grey
2 • 8
2.7
170
< 4
-5 +50
>
30
10
P.p (bars)
7
-
-
-
-
-
l
P.a (bars)
S = a
S = a . b
47
4

Related parts for 81506710