AC220 Fluke Electronics, AC220 Datasheet - Page 41
AC220
Manufacturer Part Number
AC220
Description
CLIP ALLIGATOR SUREGRIP SMALL
Manufacturer
Fluke Electronics
Series
SureGrip™r
Type
Alligator, Safety, Smallr
Datasheet
1.BP880.pdf
(72 pages)
Specifications of AC220
Voltage - Rated
600V, 1000V
Current Rating
10A
Color
Black and Red
Insulation
Insulated
Plating
Nickel
Material - Insulation
Rubber
Ratings
CAT IV, CAT III
For Use With
614-1086 - MULTIMETER INDUSTRIAL614-1048 - ELECTRICAL TESTER W/RESISTANCE614-1047 - ELECTRICAL TESTER614-1042 - DMM INDUSTRIAL TRUE-RMS W/TEMP614-1011 - MULTMTR ELEC DMM W/NON CNT VOLT614-1010 - MULTMETR DMM 6000CNT 600V614-1009 - MULTMETR ELEC DMM 6000CNT 600V
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
1610103
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
AC220D05DC-10W
Manufacturer:
MINMAX
Quantity:
12 000
Company:
Part Number:
AC220D05DC-20W
Manufacturer:
HLDY
Quantity:
12 000
Company:
Part Number:
AC220D05DC-30W
Manufacturer:
HLDY
Quantity:
12 000
Company:
Part Number:
AC220D05DC-6W
Manufacturer:
HLDY
Quantity:
12 000
Company:
Part Number:
AC220D09DC-10W
Manufacturer:
HLDY
Quantity:
12 000
Specifications – 717 and 718 Calibrators
For more information and detailed specifications, go to www.fluke.com/pressure
Recommended accessories – 717 and 718 Calibrators
717-1
718-1G
717-30G
718-30G
717-100G
718-100G
717-300G
718-300G
717-500G
717-1000G
717-1500G
717-3000G
717-5000G
Pressure accuracy
mA measurement
Loop power
In-Line Filter
See page 69
700ILF
Low Pressure
Range
+/- 1 psi, 27.5 in H
(-7 - +7 kPa)
-12 to + 30 psi,
(-83 to 207 kPa)
-12 to + 100 psi,
(-83 to 690 kPa)
-12 to +300 psi,
(-83 to +2070 kPa)
0-500 psi, 0-3450 kPa
0-1000 psi, 0-6900 kPa
0-1500 psi, 0-10342 kPa
0-3000 psi, 0-20700 kPa
0-5000 psi, 0-34500 kPa
0.05 % of range
0-24 mA range
24 V dc
See page 69
Test Pump
700LTP
Pressure Calibrators
Fluke 718 Pressure Calibrators
New!
30 and 100 psi models previously available
•
•
•
•
•
•
•
•
Intrinsically safe 718 version available (see page 45)
Fluke 717 Pressure Calibrators
Now with 9 ranges: 1, 30, 100, 300, 500, 1000,
1500, 3000 and 5000 psi
•
•
•
•
•
Fluke 718 and 717
2
0,
pressure calibration tools
Compact size, lightweight
New built-in pressure switch test feature
Built-in pressure/vacuum hand pump, with vernier
and bleed valve
Pressure and vacuum measurement to 0.05 % of full
span, using an internal pressure sensor (dry air only)
Pressure measurement to 10,000 psi/700 bar using
any of 29 Fluke 700Pxx Pressure Modules
Measure mA with 0.015 % accuracy and 0.001 mA
resolution, while providing 24 volt loop power supply
1⁄8 inch NPT female pressure fitting
Min/Max/Hold functions
Measure pressure and vacuum to 0.05 % of full scale
with internal 30 or 100 psig sensor
– 1/8 NPT pressure fitting
– Compatible with non-corrosive gasses and liquids
Measure pressure to 10,000 psi/69 mPa using one of
29 Fluke 70Pxx Pressure Modules
Measure mA with 0.015 % accuracy and 0.001 mA
resolution, while providing 24 V loop power
New built-in pressure switch test feature
Min/Max/Hold functions
SureGrip Industrial
Test Lead Set
See page 61
1 psi and 300 psi models in addition to the
Compact, professional,
TL0
Resolution
+0.0001 psi, 0.0001 kPa,
0.0001 in H
0.001 psi, 0.001 kPa, 0.001
in H
0.01 psi, 0.01 kPa, 0.01 in H
0.01 psi, 0.01 kPa, 0.01 in H
0.01 psi, 0.1 kPa
0.01 psi, 0.1 kPa
0.1 psi, 1 kPa
0.1 psi, 1 kPa
0.1 psi, 1 kPa
0.001 mA resolution
2
0
2
0
C5 (717 only)
Large Soft Case
See page 70
2
2
0
0
Comment
Fluke-718 dry air only and
includes on board pump
Fluke-718 dry air only and
includes on board pump
Fluke-718 dry air only and
includes on board pump
Fluke-718 dry air only and
includes on board pump
Compatible with non-corrosive
gases and fluids
Compatible with non-corrosive
gases and fluids
Compatible with non-corrosive
gases and fluids
Compatible with non-corrosive
gases and fluids
Compatible with non-corrosive
gases and fluids
Accuracy: ± 0.015 % + 1 count
Accuracy: ± 10 %
Hydraulic Test Pump
See page 69
700HTP
Fluke 700 Series
Pressure Modules
•
•
•
•
•
•
•
•
*for use with 718Ex and 725Ex only
(see page 45 for more information)
Application note, literature code
2577485:
Pressure calibration with the
Fluke 718
New design pro-
tects on-board
pump from fluid
damage. This
application note
explains how
to drain pres-
sure lines safely
before calibra-
tion, and how to
clean the pres-
sure pump on the
new Fluke 718.
Want to read more? Download
this and other application notes
at www.fluke.com/library
29 pressure modules
8 intrinsically safe pressure modules*
Ranges from 1.000 in H
(0.2491 kPa) to 10,000 psi
(68.948 MPa)
Gage, differential, dual (compound),
absolute, and vacuum modules
Rugged cases protect the modules
from harsh environments
Full-accuracy performance from
0 °C to 50 °C
Pressure readings update twice per
second, and may be displayed in
up to 11 different units
One-year warranty
Included accessories
Fluke 718 and 717: Protective
yellow holster, test leads and
alligator clips, single 9 V alkaline
battery (two 9 V batteries in 718)
and instructions.
Ordering information
Fluke-718 30US Pressure Calibrator
Fluke-718 100US Pressure Calibrator
Fluke-718 1G
Fluke-718 300G Pressure Calibrator
Fluke-717 30G
Fluke-717 100G Pressure Calibrator
Fluke-717 1G
Fluke-717 300G Pressure Calibrator
Fluke-717 500G Pressure Calibrator
Fluke-717 1000G Pressure Calibrator
Fluke-717 1500G Pressure Calibrator
Fluke-717 3000G Pressure Calibrator
Fluke-717 5000G Pressure Calibrator
Pressure
Enabled
Process Calibration Tools
Pressure Calibrator
Pressure Calibrator
Pressure Calibrator
2
0
Fluke Process
Calibrators in
this catalog
displaying
the Pressure
Enabled symbol
display readings
from the 700
Series Pressure
Modules.
Pressure
Enabled
1