FLUKE-27YEL Fluke Electronics, FLUKE-27YEL Datasheet - Page 28

no-image

FLUKE-27YEL

Manufacturer Part Number
FLUKE-27YEL
Description
MULTIMETER YELLOW COLOR
Manufacturer
Fluke Electronics
Series
TouchHold®, 20r
Type
Digital (DMM)r
Datasheet

Specifications of FLUKE-27YEL

Includes
Battery, Clips, Test Leads
Style
Handheld
Display Digits
3.75
Display Type
LCD, Bar Graph
Display Count
3200
Function
Voltage, Current, Resistance
Functions, Extra
Continuity, Diode Test
Features
Hold, MIN/MAX
Ranging
Auto/Manual
Response
Average
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
739169
27
Users Manual
Basic electrical accuracy is specified from 18°C to 28°C with relative humidity up to 95%, for a period of one year after
calibration. All ac conversions are ac coupled, average responding, and calibrated to read the true rms value of a sine wave
input.
Ranging is either automatic or manual in all functions with more than one range. Test resistance below approximately 270 e
in the Diode test function produces a continuous audible tone.
24
* Accuracy is specified as ±([% of reading] + [number of least significant digits]).
40-1000 Hz
40-1000 Hz
Function
32.00 mA
320.0 mA
10.00 A
320.0 µA
3200 µA
32.00 mA
320.0 mA
10.00 A
320.0 µA
3200 µA
Range
0.01 mA
0.1 mA
0.01 A
0.1 µA
1 µA
0.01 mA
0.1 mA
0.01 A
0.1 µA
1 µA
Resolution
±(0.75%+2)
±(0.75%+2)
±(1.5%+2)
±(1.5%+2)
±(0.75%+2)
±(0.75%+2)
±(0.75%+2)
±(1.5%+2)
±(1.5%+2)
±(1.5%+2)
Accuracy
Typical Burden Voltage
5.6 mV/mA
5.6 mV/mA
50 mV/A
0.5 mV/µA
0.5 mV/µA
5.6 mV/mA
5.6 mV/mA
50 mV/A
0.5 mV/µA
0.5 mV/µA