ACD-31P Amprobe, ACD-31P Datasheet - Page 2

no-image

ACD-31P

Manufacturer Part Number
ACD-31P
Description
MTR CLMPON TRMS BCKLGT 1000A
Manufacturer
Amprobe
Type
Digital (DMM)r
Datasheet

Specifications of ACD-31P

Includes
Battery, Case, Test Leads
Style
Clamp
Display Digits
3.83
Display Type
LCD
Display Count
Varies
Function
Voltage, Current, Resistance, Temperature, Frequency
Functions, Extra
Continuity
Features
Auto Off, Backlight, Hold, Voltage Indicator
Ranging
Auto
Response
True RMS
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
2730736
Update Rate:
Power function: 1 per second nominal
Voltage, ACA clamp-on, Ohm, Hz & Temperature
functions: 4 per second nominal
Polarity: Automatic
Low Battery: Below approx. 2.4V
Operating Temperature: 0˚C to 40˚C
Relative Humidity: Maximum relative humidity
80% for temperature up to 31˚C decreasing
linearly to 50% relative humidity at 40˚C
Altitude: Operating below 2000m
Storage Temperature: -20˚C to 60˚C, < 80%
R.H. (with battery removed)
Temperature Coefficient: nominal 0.15 x (spec-
ified accuracy)/ ˚C @(0˚C -18˚C or
28˚C -40˚C), or otherwise specified
Sensing: True RMS sensing for all models
Safety: Meets IEC61010-2-032 (1994),
EN61010-2-032(1995), UL3111-2-032(1999).
Measurement Category: III 600 Volts ac & dc
www.AMPROBE.com
Transient protection: 6.5kV (1.2/50 s surge)
for all models
Pollution degree: 2
E.M.C.: Meets EN61326(1997, 1998/A1),
EN61000-4-2(1995), and EN61000-4-3(1996)
an RF field of 3V/m:
Total Accuracy = Specified Accuracy + 45 digits
erformance above 3V/m is not specified
Overload Protections: ACA Clamp-on jaws: AC
1000A rms continuous + & COM terminals (all
functions): 600VDC/VAC RMS
Power Supply : standard 1.5V AAA Size (NEDA
24A or IEC LR03) battery X 2
Power Consumption: Voltage, ACA, Hz &
Power functions: 10mA typical
HM & Temperature functions: 4mA typical
APO Timing: Idle for 17 minutes
APO Consumption: 10 A typical
Dimension: L224mm X W78mm X H40mm
Weight: 224 gm approx
These instruments combine the standard features of
professional clamp-on meters, with full Power
analyzing capabilities! Measure: Active (W), Reactive
(VAR) and Apparent (VA) Powers along with dual dis-
play Power Factor readout. Increase measuring
efficiency with an optional PC interface kit.
PC Interface kit (PC connection cable with software) RS-232 KIT2
OPTIONAL ACCESSORIES
Line splitter (Energizer)
5000A Clamp-on Current Transformer (50 to 1) CT50-1
3000A Clamp-on Current Transformer (50 to 1) CT50-2
Dual input Thermocouple adapter with two ther-
mocouples -50°F to 600°F
Alligator Clips (For test leads)
REPLACEMENT PARTS
Test leads with set of alligator clips
(supplied with product)
(alligator clips are not supplied with product)
Thermocouple
Carrying case
Instruction Manual
CAT
600V
Jaw opening & Conductor diameter: 45mm max
Special features: Backlight display (model ACD-
31P & ACD-41PQ only); AutoVATM
(Auto Selection on ACV, DCV or ACA functions);
Power measurement of selectable W,
VAR & VA with dual-display Total Power Factor
features; Total harmonic distortion THD%-F
(model ACD-41PQ only); PEAK-rms HOLD
ELECTRICAL SPECIFICATIONS
Accuracy is ±(% reading digits + number of dig-
its) or otherwise specified, at 23 oC ±5 oC
less than 75% R.H. & True RMS (all models)
ACV & ACA clamp-on accuracies are specified
from 0% to 100% of range or otherwise speci-
fied. Maximum Crest Factor is as specified
below, and with frequency spectrums, besides
fundamentals, fall within the meter specified AC
bandwidth for non-sinusoidal waveforms.
Fundamentals are specified at 50Hz and 60Hz.
TRUE
R M S
z
PART NUMBER
MTL-90B
TPK-59
SV-U
www.AMPROBE.com
PART NUMBER
A47L
DKTA-620 and
two of TPK-56
VRC-320