ACD-41PQ Amprobe, ACD-41PQ Datasheet - Page 2

DMM CLAMP-ON W/THD

ACD-41PQ

Manufacturer Part Number
ACD-41PQ
Description
DMM CLAMP-ON W/THD
Manufacturer
Amprobe
Series
AutoTect™r
Type
Digital (DMM)r
Datasheet

Specifications of ACD-41PQ

Includes
Battery, Case, Test Leads
Style
Clamp
Display Digits
3.83
Display Type
LCD
Display Count
Varies
Function
Voltage, Current, Resistance, Temperature, Frequency
Functions, Extra
Continuity
Features
Auto Off, Backlight, Hold
Ranging
Auto/Manual
Response
True RMS
Dmm Type
Clamp
Voltage Measuring Range Dc
600V
Voltage Measuring Range Ac
600V
Current Measuring Range Ac
40A To 1000A
Resistance Measuring Range
0-999.9 Ohm
Frequency Measuring Range
5Hz To 500Hz
Trms
YES
Ac Current
40/400/1000 A
Ac Current Basic Accuracy**
±(1.0 % Rdg +5 LSD) @ 50 and 60 Hz
Dc Voltage
600 V
Dc Voltage Basic Accuracy**
±(0.5 % Rdg + 5 LSD)
Ac Voltage
600 V
Ac Voltage Basic Accuracy**
±(1.0 % Rdg + 5 LSD) @ 50 / 60 Hz
Resistance
999.9 Ohms
Resistance Basic Accuracy**
±(1.0 % Rdg + 6 LSD)
Frequency
5 Hz to 500 Hz
Frequency Basic Accuracy**
±(0.5 % Rdg +4 LSD)
Thd-f *
0.0 % to 99.9 %
Thd-f * Basic Accuracy**
1.5 % of Reading + 6d @ Fund Frequency
Active Power (w)
0 to 600 kW
Reactive Power (var)
0 to 600 kVAR
Apparent Power (va)
0 to 600 kVA
Power Factor
0.10 to 0.99
Power Factor Basic Accuracy**
±3 LSD @ Harmonics Fund to 21th
Temperature
-58°F to 572°F (-50°C to 300°C)
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Lead Free Status / RoHS Status
na, Contains lead / RoHS compliant by exemption
Other names
2730760
GENERAL SPECIFICATIONS
Display: Voltage functions: 6000 counts LCD
display(s)
Power, Ohm & Hz functions: 9999 counts LCD
display(s)
ACA clamp-on function: 4000 counts LCD display(s)
Update Rate: Power function: 1 per second
nominal
Voltage, ACA clamp-on, Ohm, Hz &
Temperature functions: 4 per second nominal
ACD-40PQ Hz function: 2 per second nominal.
Polarity: Automatic
Low Battery: Below approx. 2.4V
Operating Temperature: 0˚C to 40˚C
Relative Humidity: Maximum relative humidity
80% for temperature up to 31˚C decreasing
linearly to 50% relative humidity at 40˚C
Altitude: Operating below 2000m
Storage Temperature: -20˚C to 60˚C, < 80%
R.H. (with battery removed)
Temperature Coefficient: nominal 0.15 x
(specified accuracy)/ ˚C @ (0oC -18oC or
28˚C -40˚C), or otherwise specified
Sensing: True RMS sensing for all models
Safety: Meets IEC61010-2-032 (1994),
(ACD-41PQ only)
www.AMPROBE.com
EN61010-2-032(1995), UL3111-2-032(1999).
Measurement Category: III 600 Volts ac & dc
Transient protection: 6.5kV (1.2/50 s surge)
for all models
Pollution degree: 2
E.M.C.: Meets EN61326(1997, 1998/A1),
EN61000-4-2(1995), and EN61000-4-3(1996)
In an RF field of 3V/m:
Total Accuracy = Specified Accuracy + 45 digits
Performance above 3V/m is not specified
Overload Protections:
ACA Clamp-on jaws: AC 1000A RMS
continuous + & COM terminals (all functions):
600VDC/VAC RMS
Power Supply: standard 1.5V AAA Size (NEDA
24A or IEC LR03) battery X 2
Power Consumption: Voltage, ACA, Hz & Power
functions: 10mA typical
Voltage & ACA functions: 3.5mA typical
Ohm & Temperature functions: 4mA typical
APO Timing: Idle for 16 to 17 minutes
APO Consumption: 10 A typical
Dimension: L224mm X W78mm X H40mm
Weight: 224 gm approx
Jaw opening & Conductor diameter: 45mm max
(ACD-41PQ)
The ACD-40’s provide a simple and effective way to verify if
the electrical system is affected by harmonics. Add on
troubleshooting capabilities with the ACD-40PQ data
logging feature or get complete Power analysis with the
ACD-41PQ. Increase measuring efficiency with an optional
PC interface kit.
PC Interface kit (PC connection cable with software) RS-232 KIT2
OPTIONAL ACCESSORIES
Line splitter (Energizer)
5000A Clamp-on Current Transformer (50 to 1) CT50-1
3000A Clamp-on Current Transformer (50 to 1) CT50-2
Dual input Thermocouple adapter with two ther-
mocouples -50°F to 600°F
Alligator Clips (For test leads)
REPLACEMENT PARTS
Test leads with set of alligator clips
(supplied with product)
(alligator clips are not supplied with product)
Thermocouple
Carrying case
Instruction Manual
(ACD-40PQ )
CAT
600V
Special features
AutoVATM (Auto Selection on ACV, DCV or ACA
functions); Power measurement of selectable W,
VAR & VA with dual-display Total Power Factor
features; Total harmonic distortion THD%-F;
PEAK-RMS HOLD;
Special features (ACD40PQ): Backlight display;
THD%-R Total harmonic distortion-RMS); On
screen stand-alone Hi-Lo logging (5400 minutes)
at sampling speed of faster than: 20 per second
for Voltage & ACA functions 4 per second for
Ohm & Temperature functions 2 per second for
Hz function
ELECTRICAL SPECIFICATIONS
Accuracy is ±(% reading digits + number of dig-
its) or otherwise specified, at 23 ˚C ±5 ˚C
& less than 75% R.H. True RMS (all models)
ACV & ACA clamp-on accuracies are specified
from 0% to 100% of range or otherwise speci-
fied. Maximum Crest Factor is as specified
below, and with frequency spectrums, besides
fundamentals, fall within the meter specified AC
bandwidth for non-sinusoidal waveforms.
Fundamentals are specified at 50Hz and 60Hz.
TRUE
R M S
(ACD-41PQ)
z
PART NUMBER
MTL-90B
TPK-59
SV-U
www.AMPROBE.com
: Backlight display;
PART NUMBER
A47L
DKTA-620 and
two of TPK-56
VRC-320