ACD-16 TRMS PRO Amprobe, ACD-16 TRMS PRO Datasheet - Page 2

DMM CLAMP-ON TRMS 1000A

ACD-16 TRMS PRO

Manufacturer Part Number
ACD-16 TRMS PRO
Description
DMM CLAMP-ON TRMS 1000A
Manufacturer
Amprobe
Type
Digital (DMM)r
Datasheet

Specifications of ACD-16 TRMS PRO

Includes
Battery, Case, Test Leads
Style
Clamp
Display Digits
3.83
Display Type
LCD
Display Count
Varies
Function
Voltage, Current, Resistance, Temperature, Frequency
Functions, Extra
Continuity
Features
Auto Off, Backlight, Data Logging, Hold, Voltage Indicator
Ranging
Auto
Response
True RMS
Dmm Type
Clamp
Voltage Measuring Range Dc
600V
Voltage Measuring Range Ac
600V
Current Measuring Range Ac
40A To 1000A
Resistance Measuring Range
6.000 /60.00 / 600.0 KOhm 6.000 MOhm
Lead Free Status / RoHS Status
na
Other names
2730713
705-1009
GENERAL SPECIFICATIONS
Relative Humidity: Maximum relative humidity
80% for temperature up to 31˚C decreasing lin-
early to 50% relative humidity at 40˚C
Altitude: Operating below 2000m
Storage Temperature: -20˚C to 60˚C, < 80%
R.H. (with battery removed)
Temperature Coefficient: nominal 0.15 x (spec-
ified accuracy)/ oC @(0˚C -18˚C or 28˚C -40˚C),
or otherwise specified
Sensing: Average sensing for model; True RMS
sensing for model
Safety: Meets IEC61010-2-032(1994),
EN61010-2 032(1995), UL3111-2-
032(1999).Category III 600 Volts AC & DC
Transient protection: 6.5kV (1.2/50 s surge)
for all models
Pollution degree: 2
E.M.C.: Meets EN61326(1997, 1998/A1),
EN61000-4-2(1995), and EN61000-4-3(1996)
In an RF field of 3V/m: Total Accuracy =
Specified Accuracy + 45 digits Performance
above 3V/m is not specified
Overload Protections :
ACA Clamp-on jaws: AC 1000A RMS continu-
ous + & COM terminals (all functions):
600VDC/VAC RMS
Power Supply: standard 1.5V AAA Size (NEDA
24A or IEC LR03) battery X 2
Power Consumption:
Voltage & ACA functions: 3.5mA typical
Ohm & Temperature functions: 4mA typical
APO Timing: Idle for 16 minutes
APO Consumption: 10 A typical
Dimension: L224mm X W78mm X H40mm
Weight: 224 gm approx
Jaw opening & Conductor diameter: 45mm max
Special features: Display Backlight (ACD-16
TRMS) Auto-Hold; Display Hold; On screenstand-
alone Hi-Lo logging (5400 minutes) at sampling
speed of faster than: 20 per second for Voltage &
ACA functions 4 per second for Ohm & Temperature
functions 2 per second for Hz function
Accessories: Test leads (MTL-90B), batteries
installed, user's manual, TPK-59 banana plug
type-K thermocouple & soft carrying pouch
Optional accessories: RS-232 KIT2 interface kit.
Electrical Specifications: Accuracy is ±(% read-
ing digits + number of digits) or otherwise speci-
fied, at 23 ˚C ±5 ˚C & less than 75% R.H. True
RMS Models ACD-16TRMS ACV & ACA clamp-on
accuracies are specified from 5% to 100% of
range or otherwise specified. Maximum Crest
Factor are as specified below, & with frequency
spectrums, besides fundamentals, fall within the
meter specified AC bandwidth for non-sinusoidal
waveforms. Fundamentals are specified at 50Hz
and 60Hz.
Miramar, FL 33025 • Toll Free: 800-327-5060 • Phone: 954-499-5400 • Fax: 866-287-7222 • www.Amprobe.com
www.AMPROBE.com
AC Voltage
RANGE
50Hz / 60Hz
600.0V
45Hz ~ 500Hz
600.0V
500Hz ~ 3.1kHz 9
600.0V
CMRR: >60dB @ DC to 60Hz, Rs=1k
Input Impedance: 2M , 30pF nominal
True RMS models Crest Factor:
< 2.3 : 1 at full scale & < 4.6 : 1 at half scale
DC Voltage
RANGE
600.0V
NMRR: >50dB @ 50/60Hz
CMRR: >120dB @ DC, 50/60Hz, Rs=1k
Input Impedance: 2M , 30pF nominal
Ohms
RANGE
999.9
Open Circuit Voltage: 0.4VDC typical
Audible Continuity Tester
Audible threshold: between 10 and 300 .
Response time: 250 s
Frequency
RANGE
5.00Hz ~ 500.0Hz
Sensitivity (Sine RMS)
40A range: > 4A
400A range: > 40A
1000A range: > 400A
600V range: > 30V
ACD-16 Pro & ACD-16 TRMS Pro
1000A Data-Logging Clamp-on Multimeters
(ACD-16 TRMS only)
Accuracy
0.5% + 5d
Accuracy
0.5%+4d
Accuracy
1.0% + 6d
Accuracy
1.0% + 5d
1.5% + 5d
2.5% + 5d
Temperature
RANGE
-50˚C ~ 300˚C
-58˚F ~ 572˚F
1)
-20
Type-K thermocouple range & accuracy not included
ACA Current (Clamp-on)
RANGE
50Hz / 60Hz
40.00A, 400.0A, 1000A 1.0% + 5d
45Hz ~500Hz
40.00A, 400.0A
1000A
500Hz ~ 3.1kHz
40.00A, 400.0A
1000A
True RMS models Crest Factor:
< 2.5 : 1 at full scale & < 5.0 : 1 at half scale for
40.00A & 400.0A ranges
< 1.4 : 1 at full scale & < 2.8 : 1 at half scale for
1000A range
1)
2)
3)
Add 1% to specified accuracy for measurements
made WITHIN jaw marking lines (away from
jaw opening)
Add 4% to specified accuracy for measurements
made BEYOND jaw marking lines (toward
jaws opening)
Add 3
below 10% of range
Induced error from adjacent current-carrying
conductor: < 0.06A/A
Specified accuracy is for measurements made
at the jaw center. When the conductor is not
positioned at the jaw center, position errors
introduced are:
Add 8d to specified accuracy while reading is
˚
C ~ -50
˚
C (or 6
˚
C (or @ -4
˚
F) to specified accuracy @
(ACD-16TRMS Pro only)
˚
F ~ -58
Accuracy
2.0% + 5d
2.5% + 5d
2.0% + 5d
2.5% + 5d
Accuracy
2.0% + 3˚C
2.0% + 6˚F
˚
F)
1) 2) 3)
1)