190 TPI (Test Products Int), 190 Datasheet

no-image

190

Manufacturer Part Number
190
Description
DMM AUTO-RANGE W/BOOT IND HVAC
Manufacturer
TPI (Test Products Int)
Series
190r
Type
Digital (DMM)r
Datasheets

Specifications of 190

Lead Free Status
Contains lead
Includes
Battery, Test Leads
Style
Handheld
Display Digits
4.75
Display Type
LCD, Bar Graph
Display Count
50000
Function
Voltage, Current, Resistance, Capacitance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Backlight, Hold, Min/Max, RS-232 Port, Sleep
Ranging
Auto/Manual
Response
True RMS
Other names
190TPI

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
190-009-113L007
Manufacturer:
NorComp Inc.
Quantity:
98
Part Number:
190-009-113L009
Manufacturer:
NorComp Inc.
Quantity:
98
Part Number:
190-009-113L537
Manufacturer:
NorComp Inc.
Quantity:
152
Part Number:
190-009-113L539
Manufacturer:
NorComp Inc.
Quantity:
97
Part Number:
190-009-113L567
Manufacturer:
NorComp Inc.
Quantity:
63
190 Specifications
Function
DCV
ACV
DCA/ACA
OHM
CAPACITANCE
(190,194)
CAPACITANCE
(192)
Inductance
(Only192)
Frequency
Diode
Continuity
Test Products International, Inc.
Test Voltage
Approx. 3V
Test Voltage
Approx. 3V
See pages 10~13 for detail specifications.
Range
50mV
500mV
5V
50V
500V
1000V
5V
50V
500V
750V
500µA
5000µA
50mA
500mA
5A
10A
500Ω
5kΩ
50kΩ
500kΩ
5MΩ
50MΩ
5µF
50µF
500µF
5000µF
20mF
100nF
1µF
10µF
100µF
100mH
50Hz
500Hz
5KHz
50KHz
500KHz
±0.05
% Basic DCV Accuracy
Resolution
0.001mV
0.01mV
0.0001V
0.001V
0.01V
0.1V
0.0001V
0.001V
0.01V
0.1V
0.01µA
0.1µA
0.001mA
0.01mA
0.0001mA
0.001A
0.1Ω
0.0001kΩ
0.001kΩ
0.01kΩ
0.0001MΩ
0.001MΩ
0.001µF
0.01µF
0.1µF
1µF
0.01mF
0.1nF
0.001µF
0.01µF
0.1µF
0.01mH
0.001Hz
0.01Hz
0.0001KHz
0.001KHz
0.01KHz
Test Current
Approx. 1mA
Threshold
300 Digits
Digital Multimeter
Instruction Manual
190
Series

190 Summary of contents

Page 1

... Specifications % Basic DCV Accuracy ±0.05 Function Range Resolution DCV 50mV 0.001mV 500mV 0.01mV 5V 0.0001V 50V 0.001V 500V 0.01V 1000V 0.1V ACV 5V 0.0001V 50V 0.001V 500V 0.01V 750V 0.1V DCA/ACA 500µA 0.01µA 5000µA 0.1µA 50mA 0.001mA 500mA ...

Page 2

TABLE OF CONTENTS A. INTRODUCTION 1. Congratulations ··············· 2. Product Description ············ Declaration of Conformity B. SAFETY CONSIDERATIONS ········· C. TECHNICAL DATA 1. Features and Benefits ··········· 2. Product Applications ··········· 3. Specifications ················ D. MEASUREMENT TECHNIQUES 1. ...

Page 3

... Test Lead Set Instruction Manual Declaration of Conformity This is to certify that model DMM 190 conforms to the protection requirement of the council directive 89/336/EEC, in the approximation of laws of the member states relating to Electromagnetic compatibility and 73/23/EEC, the low voltage Directive by application of the following standards: ...

Page 4

B. SAFETY CONSIDERATIONS WARNING! : Please follow manufacturers test procedures whenever possible. Do not attempt to measure unknown voltages or components until a complete understanding of the circuit is obtained. GENERAL GUIDELINES ALWAYS • Test the meter before using to ...

Page 5

C. TECHNICAL DATA 1. Features and benefits Safety Meets CE and IEC 1010 requirements. UL Listed to U.S. and Canadian Safety Standards. True RMS Needed to accurately measure non- sinusoidal AC voltage and current waveforms found on many controls and ...

Page 6

... Specifications IEC 1010 Over Voltage: (190, 192) CAT II-1000VDC, 750VAC CATIII-600V Pollution Degree 2 EC 1010 Over Voltage: (194) CATIII-1000V CATIV-600V Pollution Degree 2 ※ INSTALLATION I·II·III INSTALLATION CATEGORY(OVERVOLTAGE CATEGORY Signal level, special equipment or parts of equipment, telecommunication, electronic etc., with smaller transient overvoltages than INSTALLATION CATEGORY II. ...

Page 7

... Fuse(fast blow) F600V, 0.5A 31CM F1000V, 0.44A (Only 194) g. Continuity Buzzer Test voltage 3V F600V, 10A 31CM F1000V, 11A (Only 194) h. Capacitance (190, 194) Range Overload protection 5uF 50uF F600V, 0.5A 31CM 500uF F1000V, 0.44A 5000uF 1uF (Only194) 20mF Fuse(fast blow) F600V, 10A 31CM h-1 ...

Page 8

Specifications (cont.) j. frequency Range Resolution Accuracy 50Hz 0.001Hz 500Hz 0.01Hz +/-0.05% of reading, 600V 5Khz 0.0001Khz +/- 5digits 50Khz 0.001Khz 500Khz 0.01Khz k. Adaptor Model A301(Temp Adaptor C/F) 1mV/C, 1mV/F 0000.0 C/F A254(Current Adaptor 10/60A) ...

Page 9

... Connect the red test lead from the meter to the positive (+) terminal of the battery. • Connect the black test lead to the negative (-) terminal of the battery. • Reconnect power to the circuit and read the voltage on the 190. 16 ...

Page 10

Step by step procedure a. Measuring DC Volts CAUTION Do not attempt to make a voltage measurement if a test lead is plugged in the input jack. Instrument damage and/or personal injury may result. WARNING! Do ...

Page 11

Measuring AC Volts CAUTION Do not attempt to make a voltage measurement if a test lead is plugged in the A or umA input jack. Instrument damage and/or personal injury may result. WARNING! Do not attempt to make a ...

Page 12

Application Notes When measuring the DC current of a flame controller, follow the steps under “Measurement Procedure” above and then proceed with the following: • Set up the meter for making a µA measurement. • Connect the meter to the ...

Page 13

Measuring Resistance WARNING! Do not attempt to make resistance measurements with circuit energized. For best results, remove the resistor completely from the circuit before attempting to measure it. NOTE: To make accurate low ohm measurements, short the ends of ...

Page 14

Continuity Buzzer WARNING! Do not attempt to make continuity measurements with circuit energized. Instrument set-up: I FUNCTION BLACK TEST LEAD COM Measurement Procedure: 1. Disconnect power to circuit to be measured. COM 2. Plug black test lead into the ...

Page 15

Measuring Inductance (Only 192) FUNCTION BLACK RED TEST LEAD TEST LEAD mH COM umAmH Measurement Procedure: 1. Disconnect power to circuit to be measured. COM 2. Plug black test lead into the 3. Plug red test lead into the ...

Page 16

Record Mode The record mode saves minimum (MIN) and maximum (MAX) values measured for a series of readings. The main part of the LCD displays the actual reading, the MAX value is constantly displayed on the lower left hand ...

Page 17

Relative % Mode The Relative % mode takes the actual reading on the main display and compares reference value programmed by the user on the right hand sub-display. The left hand sub- display will show the ...

Page 18

Push button code Push key Code RANGE RANGE AUTO/ RANGE MANUAL REC REC ON/ REC AVG/ REC OFF REL REL ON ref2/ REL OFF COMP COMP ON ref1 ref2/ COMP OFF HOLD HOLD ON/ HOLD OFF ) ref1 is the ...

Page 19

E. ACCESSORIES Standard Accessories 9 Volt Alkaline Battery Fuse 0.5A Fuse 0.44A(Only194) Fuse 10A Fuse 11A(Only194) Test lead Rubber boot Optional Accessories Accessories Demonstration Software Deluxe Test lead set IEC 1010 Deluxe test lead kit Temperature Adaptor Current Adaptor 10/60A ...

Page 20

... SW Allen Blvd., Ste. 104 Beaverton, OR USA 97005 503-520-9197 • Fax: 503-520-1225 •tpiusa@msn.com Test Products International, Ltd. 2 Newcourt Business Park Perry Road Harlow, Essex CM18 7PR England Tel: 01279 439647 • Fax: 01279 450553 L190 • 1/26/04 copyright ⓒ 2004 Test Products International, Inc. ...