275 TPI (Test Products Int), 275 Datasheet - Page 15
Specifications of 275
Includes
Battery, Case, Fuse, Temperature Probe, Test Leads
Style
Clamp
Display Digits
4.5
Display Type
LCD, Bar Graph
Display Count
11000
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Hold, Min/Max, Record, Voltage Indicator
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2750
Manufacturer:
JRC
Quantity:
20 000
Part Number:
2750248
Manufacturer:
TELECOIL
Quantity:
20 000
Company:
Part Number:
275051939
Manufacturer:
FUJ
Quantity:
6 246
Company:
Part Number:
2751000001
Manufacturer:
Wickmann
Quantity:
5 288
Part Number:
27523
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
27524
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
27524A
Manufacturer:
TI/德州仪器
Quantity:
20 000
Measuring AC Voltage
Instrument set-up:
FUNC.
Measurement Procedure:
1. Disconnect power to circuit to be measured.
2. Plug black test lead into the COM input jack.
3
4. Set rotary switch to the V range.
5. Connect test leads to circuit to be measured.
6. Reconnect power to circuit to be measured.
7. Read the voltage on the 275.
Optional Modes
•
•
•
D-H:
MAX/MIN:
P-H:
Plug red test lead into the V/
600V or of a voltage level that is unknown. Make sure the tem-
perature probe is NOT plugged in during this test.
WARNING!
Do not attempt to make a voltage measurement of more than
BLACK
TEST LEAD TEST LEAD
COM
Freezes the reading on the LCD.
Records minimum and maximum measurements.
Displays peak voltage.
(See Other Features Section)
RED
V/Ω
Ω
MIN
READING
0.1mV
input jack.
MAX
600V
READING
15