270 TPI (Test Products Int), 270 Datasheet - Page 16

CLAMP-ON TESTER W/DMM

270

Manufacturer Part Number
270
Description
CLAMP-ON TESTER W/DMM
Manufacturer
TPI (Test Products Int)
Series
270r
Type
Digital (DMM)r
Datasheets

Specifications of 270

Includes
Battery, Case, Temperature Probe, Test Leads
Style
Clamp
Display Digits
3.75
Display Type
LCD, Bar Graph
Display Count
4000
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Hold, Min/Max, Sleep
Ranging
Auto/Manual
Response
Average
Lead Free Status / RoHS Status
Vendor undefined / Vendor undefined
Other names
290-1421
TPI 270
TPI270

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
270
Manufacturer:
TOKO
Quantity:
8 832
Part Number:
270
Manufacturer:
TOKO
Quantity:
1 000
Part Number:
270
Manufacturer:
UC
Quantity:
20 000
Part Number:
270-340-0252
Manufacturer:
IR
Quantity:
387
Part Number:
270-340-0402
Manufacturer:
SEMIKRON
Quantity:
23
Part Number:
270-AB
Manufacturer:
WAK
Quantity:
5 169
Part Number:
2700304.1
Manufacturer:
TMS
Quantity:
4
Part Number:
27003554-00100
Manufacturer:
ST
0
Part Number:
27003554004-100
Manufacturer:
ST
0
Measuring Resistance
Instrument set-up:
FUNC.
W
Measurement Procedure:
1. Disconnect power to circuit to be measured.
2. Plug black test lead into the COM input jack.
3. Plug red test lead into V/
4. Set the rotary switch to the
5. Connect test leads to circuit to be measured.
6. Read the resistance value on the 270.
Optional Modes
Do not attempt to make resistance measurements with circuit
energized. For best results, remove the resistor completely from
circuit before attempting to measure it. Make sure the tempera-
ture probe is NOT plugged in during this test.
NOTE:
To make accurate low ohm measurements, short the ends of the
test leads together and press the REL button to store the reading.
This will deduct the stored value from subsequent measurements
eliminating the test lead resistance from the reading.
D-H:
16
WARNING!
BLACK
TEST LEAD TEST LEAD
COM
Freezes the reading on the LCD.
(See Other Features Section)
RED
V/W
W
input jack.
W
MIN
READING
0.1W
function.
MAX
40.00MW
READING