291 TPI (Test Products Int), 291 Datasheet - Page 4

no-image

291

Manufacturer Part Number
291
Description
MANUAL DGTL CLAMP W/TEST LEADS
Manufacturer
TPI (Test Products Int)
Series
291r
Type
Digital (DMM)r
Datasheets

Specifications of 291

Includes
Battery, Case, Test Leads
Style
Clamp
Display Digits
3.75
Display Type
LCD
Display Count
4000
Function
Voltage, Current, Resistance
Functions, Extra
Continuity
Features
Hold
Ranging
Manual
Response
Average
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
291-H36AB
Manufacturer:
WAK
Quantity:
4 909
Part Number:
291000256811+
Quantity:
22
Part Number:
29102C
Manufacturer:
MURATA/村田
Quantity:
20 000
Part Number:
29103C
Manufacturer:
MURATA/村田
Quantity:
20 000
Part Number:
29104
Manufacturer:
ST
0
Part Number:
29104C
Manufacturer:
MURATA/村田
Quantity:
20 000
Part Number:
29105C
Manufacturer:
MURATA/村田
Quantity:
20 000
Part Number:
2911-0033
Manufacturer:
MOLEX
Quantity:
930
Part Number:
2911-0042
Manufacturer:
N/A
Quantity:
42 425
Part Number:
2911-0042
Manufacturer:
SMD
Quantity:
35 000
Company:
Part Number:
2911-05-321
Quantity:
129
3. EC Declaration of Conformity
4
This is to certify that TPI Model 291 conforms to the
protection requirements of the council directive
89/336/EEC, in the approximation of laws of the member
states relating to Electromagnetic compatibility and
73/23/EEC. The Low Voltage Directive by application of
the following standards:
EN 50081-1
EN 50082-1
EN 61010-1
EN 61010-2-031
EN 61010-2-032
To ensure conformity with these standard, this instru-
ment must be operated in accordance with the instruc-
tions and specifications given in this manual.
CAUTION: Even though this instrument complies with
the immunity standards, it’s accuracy can be affected
by strong radio emissions not covered in the above
standards. Sources such as hand-held radio trans-
ceivers, radio and TV transmitters, vehicle radios and
cellular phones generate electromagnetic radiation
that could be induced into the test leads of this instru-
ment. Care should be taken to avoid such situations or
alternatively, check to make sure that the instrument is
not being influence by these emissions.
CAUTION: Please follow manufacturers test proce-
dures whenever possible. Do not attempt to measure
unknown voltages or components until a complete
understanding of the circuit is obtained.
1992 Emissions Standard
1992 Immunity Standard
1993 Safety Standard
1995 Safety Standard
1995 Safety Standard