2706B B&K Precision, 2706B Datasheet

DMM W/TEMP MANUAL RANGING TOOL

2706B

Manufacturer Part Number
2706B
Description
DMM W/TEMP MANUAL RANGING TOOL
Manufacturer
B&K Precision
Series
Tool Kit®r
Type
Digital (DMM)r
Datasheets

Specifications of 2706B

Includes
Battery, Hanger, Temperature Probe, Test Leads
Style
Handheld
Display Digits
3.5
Display Type
LCD
Display Count
2000
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Backlight
Ranging
Manual
Response
Average
Lead Free Status / RoHS Status
Vendor undefined / Vendor undefined
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Vendor undefined / Vendor undefined
Other names
BK2706B
SAFETY INFORMATION
The following safety information must be observed to ensure maximum personal
safety during the operation at this meter:
Use the meter only as specified in this manual or the protection provided by the
meter might be impaired.
Test the meter on a known voltage before using it to determine if hazardous
voltage is present.
Do not use the meter if the meter or test leads look damaged, or if you suspect
that the meter is not operating properly.
Never ground yourself when taking electrical measurements. Do not touch
exposed metal pipes, outlets, fixtures, etc., which might be at ground potential.
Keep your body isolated from ground by using dry clothing, rubber shoes, rubber
mats, or any approved insulating material.
Turn off power to the circuit under test before cutting, unsoldering, or breaking
the circuit. Small amounts of current can be dangerous.
Use caution when working above 60V dc or 30V ac rms. Such voltages pose a
shock hazard.
When using the probes, keep your fingers behind the finger guards on the
probes.
Measuring voltage which exceeds the limits of the multimeter may damage the
meter and expose the operator to a shock hazard. Always recognize the meter
voltage limits as stated on the front of the meter.
OPERATING INSTRUCTIONS
DIGITAL MULTIMETER
A
MODEL 2706B
F
V
2706B
COM
Hz V
V
A
SPECIFICATIONS
Display: 3½ digit liquid crystal display (LCD) with a maximum reading of 1999.
Polarity: Automatic, positive implied, negative polarity indication.
Overrange: (OL ) or (-OL) is displayed.
Zero: Automatic.
Low battery indication: The "
Measurement rate: 2.5 times per second, nominal.
Auto power off: Approx. 25 minutes.
Operating environment: 0℃ to 50℃ at < 70% relative humidity.
Storage temperature: -20℃ to 60℃, 0 to 80% relative humidity.
Accuracy: Stated accuracy at 23 ℃±5℃, < 75% relative humidity.
Temperature Coefficient: 0.1 x (specified accuracy) per ℃. (℃ to 18℃, 28℃ to
Altitude: 6561.7 feet (2000m).
Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22.
Battery life: 150 hours typical with carbon-zinc.
Dimensions: 165mm (H) x78mm (W) x42.5mm (D).
Weight: Approx. 10.0 oz.(285g) including holster.
Accessories: One set tes t leads, one spare fuse, 9V battery (installed), and
DC VOLTS
Ranges: 200mV, 2000mV, 20V, 200V, 1000V
Resolution: 0.1mV
Accuracy: ± ( 0.5% rdg + 1 dgt)
Input impedance: 10MΩ
Overload protection: 1000VDC or 750VAC rms
600VDC/AC rms 15 seconds on 200mV range
AC VOLTS
Ranges: 200mV, 2000mV, 20V, 200V, 750V
Resolution: 0.1mV
Accuracy:
Input impedance: 10MΩ
Overload protection: 1000VDC or 750VAC rms
600VDC/AC rms 15 seconds on 200mV range
CURRENT
Ranges: 200uA, 20mA, 200mA
Resolution: 0.1uA
DC accuracy: ± ( 1.0% rdg + 1 dgts)
AC accuracy: (50Hz ~ 500Hz)
Input protection: 0.25A/500V fast blow ceramic fuse
RESISTANCE
Ranges: 200Ω , 2kΩ , 200kΩ , 20MΩ
Resolution: 0.1Ω
Accuracy:
Open circuit volts: 0.3Vdc (3.0Vdc on 200Ωrange)
Overload protection: 500VDC or AC rms
CONTINUITY
Audible indication: Less than 100Ω
Response time: 100ms
Overload protection: 500VDC or AC rms
DIODE TEST
Test current: Approx. 1.0mA
Accuracy: ±(1.5% rdg + 3dgts)
Open circuit volts: 3.0Vdc typical
Overload protection: 500VDC or AC rms
CAPACITANCE
Ranges: 200uF, 2mF, 20mF
Resolution: 0.1uF
Accuracy: ±(4% rdg + 10 dgts)
Test frequency: 21Hz
Test voltage: <3.0V
Input protection: 0.25A/500V fast blow ceramic fuse
FREQUENCY
Range: 10Hz to 40kHz
Resolution: 1Hz
Accuracy: ±(0.1% rdg + 3 dgts)
Sensitivity: 3.5V RMS min
Overload protection: 500VDC or AC rms
below the operating level.
50℃).
Operating Instructions.
± ( 1.2% rdg + 5 dgts) on 200mV to 20V ranges
± ( 2.0% rdg + 5 dgts) on 200V, 750V ranges
± ( 1.5% rdg + 5 dgts)
± ( 1.0% rdg + 4 dgts) on 200Ωto 200kΩranges
± ( 2.0% rdg + 4 dgts) on 20MΩrange
(50Hz - 500Hz)
(Autoranging)
" is displayed when the battery voltage drops
TEMPERATURE
Ranges: -35℃ ~ 750℃, -30℉~ 1400℉
Resolution: 0.1℃, 0.1℉
Accuracy:
Sensor type: K-type thermocouple
Overload protection: 60VDC or 30V AC rms
OPERATION
Before taking any measurements, read the Safety Information Section. Always
examine the instrument for damage, contamination (excessive dirt, grease, etc.)
and defects. Examine the test leads for cracked or frayed insulation. If any
abnormal conditions exist do not attempt to make any measurements.
MAX/MIN
Press MAX/MIN once begins recording MIN and MAX.
Press MAX/MIN to select current reading MIN or MAX.
Hold down for 2 seconds to exit MAX/MIN function.
Backlight
Press the
Voltage Measurements
1.Connect the red test lead to ”VΩ ” jack and the black test lead to the ”COM”
2.Set the Function/Range switch to the desired voltage type (AC or DC) and
3.Connect the test leads to the device or circuit being measured.
4. For dc, a (-) sign is displayed for negative polarity; positive polarity is implied.
Current Measurements
1.Connect the red test lead to the ”mA” jack and the black test lead to the
2.Set the Function/Range switch to the DC or AC ranges.
3.Remove power from the circuit under test and open the normal circuit path
4.Apply power and read the value from the display.
Resistance and Continuity Measurements
1.Set the Function/Range switch to the desired resistance range or continuity
2.Remove power from the equipment under test.
3.Connect the red test lead to the “ VΩ” jack and the black test lead to
4.Touch the probes to the test points. In ohms, the value indicated in the display
Diode Tests
1.Connect the red test lead to the “ VΩ” jack and the black test lead to
2.Set the Function/Range switch to the “
3.Turn off power to the circuit under test. External voltage across the
components causes invalid readings.
4.Touch probes to the diode. A forward-voltage drop is about 0.6V (typical for a
5.Reverse probes. If the diode is good, “OL” is displayed. If the diode is shorted,
6. If the diode is open, “OL” is displayed in both directions.
Capacitance Measurements
1. Set the Function/Range switch to the desired F (capacitance) range.
2.Connect the red test lead to the “F “ jack and the black test lead to the
3.Touch the probes to the capacitor. Observe polarity when measuring polarized
4. Read the capacitance directly from the display.
5. Discharge the capacitor before taking capacitance measurements.
Frequency Measurements
1. Set the Function/Range switch to the “40kHz” position.
2. Connect the red test lead to the “ VΩ” jack and the black test lead to the
3. Connect the test leads to the point of measurement and read the frequency
jack.
range. If magnitude of voltage is not known, set switch to the highest range
and reduce until a satisfactory reading is obtained.
"COM" jack.
where the measurement is to be taken. Connect the meter in series with the
circuit.
position.
the ”C O M ” jack.
is the measured value of resistance. In continuity test, the beeper sounds
continuously, if the resistance is less than 100Ω.
the ”C O M ” jack.
silicon diode).
“000” or another number is displayed.
“COM “ jack.
capacitors.
“COM “ jack.
from the display.
±(1.0% rdg + 1℃) 0℃ ~ 400℃
±(3.0% rdg + 3℃) -35℃ ~ 0℃, 400℃ ~ 750℃
±(1.0% rdg + 2℉) -4℉ ~ 750℉
±(3.0% rdg + 6℉) -30℉ ~ -4℉, 750℉ ~ 1400℉
button to activate the backlight for approximate 4.5 minutes.
“ position.
Temperature Measurements
1. Set the Function/Range switch to the desired temperature range: ℃, ℉
2. Remove leads and slide the Temp switch to the right to close lead jacks.
3.Plug any K -type thermocouple directly into the meter to measure temperature.
4. Take temperature measurement using the thermocouple probe and read the
Temp offset adjustment
MAINTENANCE
Battery Replacement
Power is supplied by a 9 volt battery. (NEDA 1604, IEC 6F22). The "
on the LCD display when replacement is needed. To replace the battery, remove
the three screws from the back of the meter and lift off the front case. Remove
the battery from case bottom.
Fuse Replacement
If no current and capacitance measurements are possible. Check for a blown
overload protection fuse. For acc ess to fuses, remove the three screws from the
back of the meter and lift off the front case.
Replace (F1/current measurements) (F2/capacitance measurements) only with
the original type 0.25A/500V, fast acting ceramic fuse.
Cleaning
Wipe the case with a damp cloth and mild detergent. Do not use abrasives or
solvents. Dirt or moisture in the terminals can affect readings.
Safety: Conforms to IEC61010-1 (EN61010-1), CATII 1000V, CATIII 600V, Class
CATII: Is for measurements performed on circuits directly connected to the
CAT III: Is for measurements performed in the building installation.
EMC: Conforms to EN61326.
The symbols used on this instrument are:
Remove test leads before changing battery or fuse or
performing any servicing.
temperature from the display.
The OFFSET control is set at the factory to allow for the variations found in
standard thermocouples. By adjusting the OFFSET control, you can optimize
measurement accuracy for a particular thermocouple at a particular
temperature.
Equipment protected throughout by Double insulation (Class II)
Alternating current
Direct current
Ground
Caution, refer to accompanying documents
II, Pollution degree 2 Indoor use.
low-voltage installation.
WARNING
" appears

2706B Summary of contents

Page 1

... SPECIFICATIONS OPERATING INSTRUCTIONS Display: 3½ digit liquid crystal display (LCD) with a maximum reading of 1999. MODEL 2706B Polarity: Automatic, positive implied, negative polarity indication. DIGITAL MULTIMETER Overrange: ( (-OL) is displayed. Zero: Automatic. Low battery indication: The " below the operating level. Measurement rate: 2.5 times per second, nominal. ...

Page 2

... INSTRUCCIONES DE FUNCIONAMIENTO Precisión: Dicho de precisió MODEL 2706B Coeficiente de temperatura: 0,1 x (exactitud especificada) por °C. (°C a MULTIMETRO DIGITAL 18°C, 28°C a 50°C). Altitud: 6561,7 pies (2000m). Potencia: El único estándar de la baterí voltios, NEDA 1604, JIS 006P, IEC 6F22. ...

Page 3

... SPECIFICATIONS Manuel d’utilisation Affichage: 3½ digits (LCD) avec un affichage de 1999 maximum Modèle 2706B Polarité: Automatique, avec indication du signe moins. Multimètre Numérique 2000 points Dépassement: (OL) ou (-OL) est affiché. Zéro: Automatique. Indication de pile usée: le symbole " qu’il faut la remplacée. ...

Page 4

... Display: 3½ -stellige Flüssigkristallanzeige (LCD) mit max. 1999 Zählimpulsen. DIGITAL-MULTIMETER Polarität: Automatisch, positive Polarität implizit, negative wird angezeigt. Bereichsüberschreitung: Anzeige von (OL) oder ( -OL). MODELL 2706B Null: Automatisch Indikator bei schwacher Batteriespannung : Sinkt die Batteriespannung unter das Betriebsniveau, wird das Symbol Messrate: Nennwert 2,5 Mal pro Sekunde. Automatische Abschaltung: nach ca. 25 Minuten Inaktivitä ...

Page 5

B&K Precision warrants to the original purchaser that its products and the component parts thereof, will be free from defects in workmanship and materials for a period of one year from date of purchase from an authorized B&K Precision distributor. ...