2703C B&K Precision, 2703C Datasheet

DMM MANUAL RANGING TOOL KIT

2703C

Manufacturer Part Number
2703C
Description
DMM MANUAL RANGING TOOL KIT
Manufacturer
B&K Precision
Series
Tool Kit®r
Type
Digital (DMM)r
Datasheets

Specifications of 2703C

Includes
Battery, Hanger, Test Leads
Style
Handheld
Display Digits
3.5
Display Type
LCD
Display Count
2000
Function
Voltage, Current, Resistance
Functions, Extra
Battery Test, Continuity, Diode Test
Ranging
Manual
Response
Average
Lead Free Status / RoHS Status
Vendor undefined / Vendor undefined
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
BK2703C
SAFETY INFORMATION
The following safety information must be observed to ensure maximum personal
safety during the operation at this meter:
Use the meter only as specified in this manual or the protection provided by the
meter might be impaired.
Test the meter on a known voltage before using it to determine if hazardous
voltage is present.
Do not use the meter if the meter or test leads look damaged, or if you suspect
that the meter is not operating properly.
Never ground yourself when taking electrical measurements. Do not touch
exposed metal pipes, outlets, fixtures, etc., which might be at ground potential.
Keep your body isolated from ground by using dry clothing, rubber shoes, rubber
mats, or any approved insulating material.
Turn off power to the circuit under test before cutting, unsoldering, or breaking
the circuit. Small amounts of current can be dangerous.
Use caution when working above 60V dc or 30V ac rms. Such voltages pose a
shock hazard.
When Using the probes, keep your fingers behind the finger guards on the
probes.
Measuring voltage which exceeds the limits of the multimeter may damage the
meter and expose the operator to a shock hazard. Always recognize the meter
voltage limits as stated on the front of the meter.
OPERATING INSTRUCTIONS
DIGITAL MULTIMETER
10A
MODEL 2703C
A
BATT 1.5V
V
mA
2703C
COM
V
V
SPECIFICATIONS
Display: 3½ digit liquid crystal display (LCD) with a maximum reading of 1999.
Polarity: Automatic, positive implied, negative polarity indication.
Overrange: (OL) or (-OL) is displayed.
Zero: Automatic.
Low battery indication: The "
Measurement rate: 2.5 times per second, nominal.
Auto power off: Approx. 25 minutes.
Operating environment: 0℃to 50℃at < 70% relative humidity.
Storage temperature: -20℃to 60℃, 0 to 80% relative humidity.
Accuracy: Stated accuracy at 23 ℃±5℃, < 75% relative humidity.
Temperature Coefficient: 0.1 x (specified accuracy) per ℃. (℃to 18℃, 28℃ to
Altitude: 6561.7 feet (2000m).
Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22.
Battery life: 200 hours typical with carbon-zinc.
Dimensions: 165mm (H) x78mm (W) x42.5mm (D).
Weight: Approx. 10.0 oz.(285g) including holster.
Accessories: One set test leads, one spare fuse, 9V battery (installed), and
DC VOLTS
Ranges: 2V, 20V, 200V, 1000V
Resolution: 1mV
Accuracy: ± ( 1.2% rdg + 1 dgt)
Input impedance: 10MΩ
Overload protection: 1000VDC or 750VAC rms
AC VOLTS
Ranges:200V, 750V
Resolution: 0.1V
Accuracy: ± ( 2.0% rdg + 5 dgts) on 200V range
Input impedance: 10MΩ
Overload protection: 1000VDC or 750VAC rms
DC CURRENT
Ranges: 2mA, 20mA, 200mA, 10A
Resolution: 1uA
Accuracy: ± (1.5% rdg + 1 dgts) on 2mA to 200mA ranges
Input protection: 0.5A/500V fast blow ceramic fuse on mA input
10A input:10A for 60 seconds maximum followed by a
RESISTANCE
Ranges: 200Ω , 2k, 20k, 200k, 20MΩ
Resolution: 0.1Ω
Accuracy:
Open circuit volts: 0.3Vdc typical, (3.0Vdc on 200Ω range)
Overload protection: 500VDC or AC rms
CONTINUITY
Audible indication: Less than 100Ω
Response time: 100ms
Overload protection: 500VDC or AC rms
DIODE TEST
Test current:
Accuracy:
Open circuit volts: 3.0Vdc typical
Overload protection: 500VDC or AC rms
BATTERY TEST
Ranges: 1.5V, 9V
Resolution: 1mV, 10mV
Accuracy: ±(3.5% rdg + 2 dgts)
Loaded current:150mA typical for 1.5V range, 5mA
Overload protection: 500V DC or AC rms on 9V range,
below the operating level.
50℃).
Operating Instructions.
± (1.5% rdg + 4 dgts) on 200 Ω to 200kΩ ranges
± (3.0% rdg + 5 dgts) on 20MΩ range
typical for 9V range
0.5A/500V fast blow ceramic fuse on 1.5V range.
± ( 2.0% rdg + 10 dgts) on 750V range
10 minutes cooling period.
±(3.0% rdg + 3dgts)
± (3.0% rdg + 3 dgts) on 10A range
10A/600V fast blow ceramic fuse on mA input
Approx. 1.0mA
(50Hz - 500Hz)
" is displayed when the battery voltage drops
OPERATION
Before taking any measurements, read the Safety Information Section. Always
examine the instrument for damage, contamination (excessive dirt, grease, etc.)
and defects. Examine the test leads for cracked or frayed insulation. If any
abnormal conditions exist do not attempt to make any measurements.
Voltage Measurements
1.Connect the red test lead to ”VΩ ” jack and the black test lead to the ”COM”
2.Set the Function/Range switch to the desired voltage type (AC or DC) and
3.Connect the test leads to the device or circuit being measured.
4. For dc, a (-) sign is displayed for negative polarity; positive polarity is implied.
Current Measurements
1.Connect the red test lead to the (uA, mA or 10A) jack and the black test lead to
2.Set the Function/Range switch to the DC or AC ranges.
3.Remove power from the circuit under test and open the normal circuit path
4.Apply power and read the value from the display.
Resistance and Continuity Measurements
1.Set the Function/Range switch to the desired resistance range or continuity
2.Remove power from the equipment under test.
3.Connect the red test lead to the “ VΩ” jack and the black test lead to
4.Touch the probes to the test points. In ohms, the value indicated in the display
Diode Tests
1.Connect the red test lead to the “ VΩ” jack and the black test lead to
2.Set the Function/Range switch to the “
3.Turn off power to the circuit under test. External voltage across the
components causes invalid readings.
4.Touch probes to the diode. A forward-voltage drop is about 0.6V (typical for a
5.Reverse probes. If the diode is good, “OL” is displayed. If the diode is shorted,
6. If the diode is open, “OL” is displayed in both directions.
Battery Test
1. Connect the red test lead to the (mA/BATT 1.5V) jack and the black test lead to
2. Set the Function/Range switch to the desired 1.5V battery test range.
3. Connect the test leads to the 1.5Vdc battery under test. Normally, a good
MAINTENANCE
Remove test leads before changing battery or fuse or performing
any servicing.
Battery Replacement
Power is supplied by a 9 volt battery. (NEDA 1604, IEC 6F22). The "
on the LCD display when replacement is needed. To replace the battery, remove
the three screws from the back of the meter and lift off the front case. Remove
the battery from case bottom.
jack.
range. If magnitude of voltage is not known, set switch to the highest range
and reduce until a satisfactory reading is obtained.
the "COM" jack.
where the measurement is to be taken. Connect the meter in series with the
circuit.
position.
the ”C O M ” jack.
is the measured value of resistance. In continuity test, the beeper sounds
continuously, if the resistance is less than 100Ω.
the ”C O M ” jack.
silicon diode).
“000” or another number is displayed.
the "COM" jack.
1.5Vdc battery will read above 1.25Vdc. Consult the battery manufacturer for
complete battery specifications to determine actual battery life remaining and
condition of battery.
WARNING
“ position.
" appears
Fuse Replacement
If no current measurements are possible. check for a blown overload protection
fuse. For access to fuses, remove the three screws from the back of the meter
and lift off the front case. Replace F1 only with the original type 0.5A/500V, fast
acting ceramic fuse, 6.35x32mm .
Replace F2 only with the original type 10A/600V, fast acting ceramic fuse,
6.35x25.4mm.
Cleaning
Wipe the case with a damp cloth and mild detergent. Do not use abrosives or
solvents. Dirt or moisture in the terminals can affect readings.
Safety: Conforms to IEC61010-1 (EN61010-1), CATII 1000V, CATIII 600V, Class
EMC: Conforms to EN61326.
The symbols used on this instrument are:
CATII: Is for measurements performed on circuits directly connected to the
CAT III: Is for measurements performed in the building installation.
Equipment protected throughout by Double insulation (Class II)
Alternating current
Direct current
Ground
Caution, refer to accompanying documents
II, Pollution degree 2 Indoor use.
low-voltage installation.

2703C Summary of contents

Page 1

... OPERATING INSTRUCTIONS MODEL 2703C SPECIFICATIONS DIGITAL MULTIMETER Display: 3½ digit liquid crystal display (LCD) with a maximum reading of 1999. Polarity: Automatic, positive implied, negative polarity indication. Overrange: (OL) or (-OL) is displayed. Zero: Automatic. Low battery indication: The " below the operating level. Measurement rate: 2.5 times per second, nominal. ...

Page 2

... Entorno operativo: 0° a 50° a <70% de humedad relativa. INSTRUCCIONES DE FUNCIONAMIENTO Temperatura de almacenamiento: -20° a 60° 80% de humedad relativa. MODELO 2703C Precisión: Dicho de precisión a 23° ± 5°, <75% de humedad relativa. Coeficiente de temperatura: 0.1 x (exactitud especificada) por °C. (°C a 18°C, MULTIMETRO DIGITAL 28° ...

Page 3

... Manuel d’utilisation Modèle 2703C SPECIFICATIONS Multimètre Numérique 2000 points Affichage: 3½ digit (LCD) avec un affichage de 1999 maximum Polarité: Automatique, avec indication du signe moins. Dépassement: (OL) ou (-OL) est affiché. Zéro: Automatique. Indication de pile usée: le symbole " qu’il faut la remplacée. ...

Page 4

... BEDIENUNGSANLEITUNG TECHNISCHE DATEN DIGITAL-MULTIMETER Display: 3½ -stellige Flüssigkristallanzeige (LCD) mit max. 1999 Zählimpulsen. MODELL 2703C Polarität: Automatisch, positive Polarität implizit, negative wird angezeigt. Bereichsüberschreitung: Anzeige von (OL) oder ( -OL). Null: Automatisch Indikator bei schwacher Batteriespannung : Sinkt die Batteriespannung unter das Betriebsniveau, wird das Symbol Messrate: Nennwert 2,5 Mal pro Sekunde. Automatische Abschaltung: nach ca. 30 Minuten Inaktivitä ...

Page 5

B&K Precision warrants to the original purchaser that its products and the component parts thereof, will be free from defects in workmanship and materials for a period of one year from date of purchase from an authorized B&K Precision distributor. ...