FLUKE-287 Fluke Electronics, FLUKE-287 Datasheet - Page 85

DMM TRUE RMS 50000CNT W/BCKLGHT

FLUKE-287

Manufacturer Part Number
FLUKE-287
Description
DMM TRUE RMS 50000CNT W/BCKLGHT
Manufacturer
Fluke Electronics
Series
28xr
Type
Digital (DMM)r
Datasheets

Specifications of FLUKE-287

Includes
Battery, Case, Clips, Software, Test Leads
Style
Handheld
Display Digits
4.5
Display Type
LCD, Bar Graph
Display Count
50000
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, dB
Features
Backlight, Data Logging, Hold, Memory, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Not applicable / RoHS non-compliant
Other names
287
614-1061
Frequency Counter Sensitivity
50 mV
500 mV
5 V
50 V
500 V
1000 V
500 A
5000 A
50 mA
400 mA
5 A
10 A
[1]
[2]
Input Range
Input Range
Maximum input = 10 x range (1000 V maximum, 2 x 10
Typical frequency bandwidth with full scale (or maximum 2 x 10
Approximate Voltage Sensitivity
Approximate Current Sensitivity
(rms sine wave)
15 Hz to 100 kHz
(rms sine wave)
15 Hz to 10 kHz
250 A
2.5 mA
25 mV
0.25 V
25 mA
0.25 A
25 A
5 mV
2.5 V
1.0 A
25 V
50 V
[1]
7
V-Hz product maximum). Noise at low frequencies and amplitudes may affect accuracy.
7
V-Hz product) rms sine wave.
AC Bandwidth
AC Bandwidth
700 kHz
300 kHz
300 kHz
100 kHz
100 kHz
100 kHz
100 kHz
100 kHz
100 kHz
1 MHz
1 MHz
1 MHz
[2]
Approximate DC Trigger
Approximate DC
Trigger Levels
20 mV & 60 mV
5 mV & 20 mV
1.4 V & 2.0 V
0.5 V & 6.5 V
5 V & 100 V
5 V & 40 V
Levels
NA
Detailed Specifications
DC Bandwidth
DC Bandwidth
600 kHz
300 kHz
300 kHz
80 kHz
1 MHz
1 MHz
NA
[2]
75